![Thies CLIMA 4.3519 Series Instructions For Use Manual Download Page 6](http://html1.mh-extra.com/html/thies-clima/4-3519-series/4-3519-series_instructions-for-use-manual_1106926006.webp)
Remark:
When using fastening adapters (angle, traverses, etc.) please take a possible
effect by turbulences into consideration.
Caution:
The device may only be supplied with a power supply of the
"Class , 2, limited power”.
5.1 Mechanical Mounting
The mounting of the wind transmitter could be done for example on a central mast tube with a Pg
21-boring thread, or on hangers or the like with a boring of
∅
29 mm. In doing so please pay
attention to possible obstacles which might effect the air flow and the measuring value.
The connecting cable or the connector is guided through the boring, and the wind transmitter is
fixed with a hexagon nut (WO 36).
5.2 Electrical Mounting
For electrical connection please refer to the connecting diagram.
5.3 Plug mounting
Applies only to instruments with connection „plug“.
Coupling socket, Typ:Binder, Serial 423, EMC with cable clamp
Cable connection: without cable shield
Cable- pull- relief
1. Stringing parts on cable acc. to plan given above.
2. Stripping cable sheath 20 mm
3. Cutting uncovered shield 20 mm
4. Stripping wire 5mm.
5. Soldering wire to the insert
6. Positioning shield in cable clamp.
7. Screwing-on cable clamp.
8. Assembling remaining parts acc. to upper plan.
9. Tightening pull-relief of cable by screw-wrench (SW16 und 17).
Cable clamp
Cable sheath
Wire
Figure 1: plug mounting
6 - 14
021075/08/11
Summary of Contents for 4.3519 Series
Page 13: ...13 14 021075 08 11...