Thies CLIMA 4.3519 Series Instructions For Use Manual Download Page 2

 

Safety Instructions

• 

Before operating with or at the device/product, read through the operating instructions. 
This manual contains instructions which should be followed on mounting, start-up, and operation.  
A non-observance might cause: 

 

 

- failure of important functions 

 

 

- Endangering of persons by electrical or mechanic effect 

 

 

- Damages at objects 

• 

Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified technician 
who is familiar with and observes the engineering regulations, provisions and standards applicable in each case. 

• 

Repairs and maintenance may only be carried out by trained staff or 

Adolf Thies GmbH & Co. KG

. Only 

components and spare parts supplied and/or recommended by 

Adolf Thies GmbH & Co. KG

 should be used for 

repairs.  

• 

Electrical devices/products must be mounted and wired only in voltage-free state. 

• 

Adolf Thies GmbH & Co KG

 guarantees proper functioning of the device/products provided that no 

modifications have been made to the mechanics, electronics or software, and that the following points are 
observed: 

• 

All information, warnings and instructions for use included in these operating instructions must be taken into 
account and observed as this is essential to ensure trouble-free operation and a safe condition of the measuring 
system / device / product.  

• 

The device / product is designed for a specific application as described in these operating instructions. 

• 

The device / product should be operated with the accessories and consumables supplied and/or recommended 
by 

Adolf Thies GmbH & Co KG

 . 

• 

Recommendation: As it is possible that each measuring system / device / product under certain conditions, and 
in rare cases, may also output erroneous measuring values, it is recommended to use redundant systems with 
plausibility checks with 

security-relevant applications

Environment 

• 

As a longstanding manufacturer of sensors Adolf Thies GmbH & Co KG is committed to the 
objectives of environmental protection and is therefore willing to take back all supplied products 
governed by the provisions of "

ElektroG

(

German Electrical and Electronic Equipment Act) 

and to perform environmentally compatible disposal and recycling. We are prepared to take 
back all Thies products concerned free of charge if returned to Thies by our customers 
carriage-paid. 

 

• 

Make sure you retain packaging for storage or transport of products. Should packaging 
however no longer be required, arrange for recycling as the packaging materials are designed 
to be recycled. 

 

Documentation 

• 

©  Copyright 

Adolf Thies GmbH & Co KG

, Göttingen / Germany 

• 

Although this operating instruction has been drawn up with due care, 

Adolf Thies GmbH & Co KG

 can accept 

no liability whatsoever for any technical and typographical errors or omissions in this document that might 
remain. 

• 

We can accept no liability whatsoever for any losses arising from the information contained in this document. 

• 

Subject to modification in terms of content. 

• 

The device / product should not be passed on without the/these operating instructions. 

 

 

2 - 14 

021075/08/11

 

 

Summary of Contents for 4.3519 Series

Page 1: ...D OF WEATHER DATA Instruction for Use 021075 08 11 Wind Transmitter compact 4 3519 xx 140 961 ADOLF THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany Box 3536 3541 37025 G ttingen Phone 551 7900...

Page 2: ...ns The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible that each measuring system device p...

Page 3: ...3 Plug mounting 6 6 Connecting Diagram 7 7 Maintenance 8 8 Technical Data 9 9 Dimension diagram 10 10 Accessories 11 11 EC Declaration of Conformity 12 Figure Figure 1 plug mounting 6 Figure 2 Connec...

Page 4: ...19 01 140 0 20 mA 0 50 m s 20 W 1 5 3 m Spiral Cable LiYY 6x0 14 mm 4 3519 02 141 4 20 mA 0 50 m s 10 W 2 m Cable 6 x 0 56 mm 4 3519 04 441 4 20 mA 0 40 m s 20 W 0 95 m PUR Cable 6 x 0 25 mm 4 3519 05...

Page 5: ...resistant materials Labyrinth gaskets protect the parts inside the instrument against precipitations 4 Recommendation Site Selection Standard Installation In general wind measurement instruments shou...

Page 6: ...hrough the boring and the wind transmitter is fixed with a hexagon nut WO 36 5 2 Electrical Mounting For electrical connection please refer to the connecting diagram 5 3 Plug mounting Applies only to...

Page 7: ...3519 40 141 4 3519 40 161 4 3519 40 167 4 3519 40 173 Separate Voltage Supply Shared Voltage Supply Order No 4 3519 10 441 Instrument without heating Pin 5 and 6 not connected Heating Power 9 13 30 V...

Page 8: ...ower 9 13 30 V DC or 24 V AC Analog Output Heating 24 V AC DC Power 24 V AC DC Analog Output Figure 3 Connecting Diagram for Models with Connector 7 Maintenance After proper mounting the instrument wo...

Page 9: ...put U 13 30 V DC oder 24 V AC DC I 0 05A P 1 5 W Electrical supply for heating 4 3519 00 01 02 04 05 20 39 xxx U 24V AC DC 45 65Hz I 0 83A P 20 W 4 3519 20 xxx U 24V AC DC 45 65Hz I 0 42A P 10 W 4 351...

Page 10: ...9 Dimension diagram Figure 4 Dimensional Drawing Model cable gland Figure 5 Dimensional Drawing Model plug 10 14 021075 08 11...

Page 11: ...ping range 116 200 mm Sensor distance 0 8 m Material Aluminium Traverse short For mounting the wind transmitter compact onto a mast 4 3171 40 000 4 3171 41 000 Clamping range 48 102 mm Clamping range...

Page 12: ...the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC 2006 95 EC DIRECTIVE 2006 95 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December...

Page 13: ...13 14 021075 08 11...

Page 14: ...THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany P O Box 3536 3541 37025 G ttingen Phone 551 79001 0 Fax 551 79001 65 www thiesclima com info thiesclima com Alterations reserved 14 14 021075 0...

Reviews: