11  EC-Declaration of Conformity 

Document-No.: 

001221

 Month: 

10 

Year: 

10 

Manufacturer: 

A D O L F   T H I E S   G m b H   &   C o.  K G

 

 Hauptstr. 76 
 D-37083 Göttingen        

 

 

 Tel.: (0551) 79001-0  

 Fax: (0551) 79001-65      
 email: [email protected] 

 
 
Description of Product:   

Wind Transmitter – compact  analog

 

 

Article No. 

4.3519.00.140 4.3519.00.141

 

4.3519.00.161 4.3519.00.167

 

4.3519.00.173 4.3519.00.361 

4.3519.00.441 4.3519.00.641 4.3519.00.740 

4.3519.00.741 4.3519.00.761 

4.3519.00.773 4.3519.00.961 4.3519.01.140 

4.3519.02.141 4.3519.02.441 

4.3519.03.141 4.3519.04.441 4.3519.05.141 

4.3519.05.161 4.3519.05.641 

4.3519.06.441 4.3519.09.141 4.3519.10.441 

4.3519.20.141 4.3519.39.141 

4.3519.40.140  

4.3519.40.141  

4.3519.40.161         

4.3519.40.167 4.3519.40.173 

4.3519.40.740 4.3519.40.741 4.3519.40.761 

4.3519.53.141 4.3519.83.141 

 

 

 

specified technical data in the document: 

021072/10/10; 021190/06/07; 021455/06/07; 021533/02/08 

 

The indicated products correspond to the essential requirement of the following European Directives and Regulations: 

 

2004/108/EC DIRECTIVE 

2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL 

of 15 December 2004 on the approximation of the laws of the Member States relating to 
electromagnetic compatibility and repealing Directive 89/336/EEC 

 

2006/95/EC DIRECTIVE 

2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL 

of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical 
equipment designed for use within certain voltage limits 

 

552/2004/EC 

Regulation (EC) No 552/2004 of the European Parliament and the Council of 10 March 2004  
on the interoperability of the European Air Traffic Management network  
(the interoperability Regulation) 

 
 
The indicated products comply with the regulations of the directives. This is proved by the compliance with the following 
standards: 

 

Reference number 

Specification 

 

 

IEC 61000-6-2: 2005 

Electromagnetic compatibility 
Immunity for industrial environment 

  

IEC 61000-6-3: 2006 

Electromagnetic compatibility 
Emission standard for residential, commercial and light industrial environments 

  

IEC 61010-1: 2001 

Safety requirements for electrical equipment for measurement, control and  
laboratory use.      Part 1: General requirements 

 
Place:  Göttingen                                                                 Date:  04.10.2010 

 

 

This declaration certificates the compliance with the mentioned directives, howe er does not include any warranty of characteristics. 

v

Please pay attention to the security advises of the provided instructions for use.

 

 

12 - 14 

021075/08/11

 

 

Summary of Contents for 4.3519 Series

Page 1: ...D OF WEATHER DATA Instruction for Use 021075 08 11 Wind Transmitter compact 4 3519 xx 140 961 ADOLF THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany Box 3536 3541 37025 G ttingen Phone 551 7900...

Page 2: ...ns The device product should be operated with the accessories and consumables supplied and or recommended by Adolf Thies GmbH Co KG Recommendation As it is possible that each measuring system device p...

Page 3: ...3 Plug mounting 6 6 Connecting Diagram 7 7 Maintenance 8 8 Technical Data 9 9 Dimension diagram 10 10 Accessories 11 11 EC Declaration of Conformity 12 Figure Figure 1 plug mounting 6 Figure 2 Connec...

Page 4: ...19 01 140 0 20 mA 0 50 m s 20 W 1 5 3 m Spiral Cable LiYY 6x0 14 mm 4 3519 02 141 4 20 mA 0 50 m s 10 W 2 m Cable 6 x 0 56 mm 4 3519 04 441 4 20 mA 0 40 m s 20 W 0 95 m PUR Cable 6 x 0 25 mm 4 3519 05...

Page 5: ...resistant materials Labyrinth gaskets protect the parts inside the instrument against precipitations 4 Recommendation Site Selection Standard Installation In general wind measurement instruments shou...

Page 6: ...hrough the boring and the wind transmitter is fixed with a hexagon nut WO 36 5 2 Electrical Mounting For electrical connection please refer to the connecting diagram 5 3 Plug mounting Applies only to...

Page 7: ...3519 40 141 4 3519 40 161 4 3519 40 167 4 3519 40 173 Separate Voltage Supply Shared Voltage Supply Order No 4 3519 10 441 Instrument without heating Pin 5 and 6 not connected Heating Power 9 13 30 V...

Page 8: ...ower 9 13 30 V DC or 24 V AC Analog Output Heating 24 V AC DC Power 24 V AC DC Analog Output Figure 3 Connecting Diagram for Models with Connector 7 Maintenance After proper mounting the instrument wo...

Page 9: ...put U 13 30 V DC oder 24 V AC DC I 0 05A P 1 5 W Electrical supply for heating 4 3519 00 01 02 04 05 20 39 xxx U 24V AC DC 45 65Hz I 0 83A P 20 W 4 3519 20 xxx U 24V AC DC 45 65Hz I 0 42A P 10 W 4 351...

Page 10: ...9 Dimension diagram Figure 4 Dimensional Drawing Model cable gland Figure 5 Dimensional Drawing Model plug 10 14 021075 08 11...

Page 11: ...ping range 116 200 mm Sensor distance 0 8 m Material Aluminium Traverse short For mounting the wind transmitter compact onto a mast 4 3171 40 000 4 3171 41 000 Clamping range 48 102 mm Clamping range...

Page 12: ...the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89 336 EEC 2006 95 EC DIRECTIVE 2006 95 EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December...

Page 13: ...13 14 021075 08 11...

Page 14: ...THIES GmbH Co KG Hauptstra e 76 37083 G ttingen Germany P O Box 3536 3541 37025 G ttingen Phone 551 79001 0 Fax 551 79001 65 www thiesclima com info thiesclima com Alterations reserved 14 14 021075 0...