Operation/installation/service manual
MACERATOR TOILETS
Manuale di utilizzo / installazione / manutenzione
TOILET MACERATRICI
X-light / Privilege/ Evolution/ Breeze/ E-Breeze/ Silence Plus 2G/ Elegance 2G
68
TECMA SRL – Via Flaminia / Loc Castel delle Formiche/ 05030 Otricoli (TR) / Italy-
rev 1.2017
1111111111111111
111111111111111111111
**refer to each model PIS to check if the bidet function is available with integrated or wall mounted mixer
Any other commercial handle/mixer can alternatively be used to mix the water
The customer is free to select a wall mounted mixer from the same collection of the bathroom,
and use it to control the bidet integrated in the toilet. In this case do not use the mixer provided
and install the mixer/handle that you prefer. Make sure to do the plumbing right. In case of any
doubt contact Tecma technicians.
4.0
Troubleshooting
4.1 Toilet is noisy
The pump may be partially blocked if a solid object or paper other than toilet paper has been
flushed. Flush repeatedly. If the problem persists, open and inspect the macerator pump. Contact
a TECMA service centre, which will provide qualified assistance. Check the position of the sleeves
if the water flow generates excessive noise, especially at the end of flushing.
4
.2 Water is added but the pump fails to flush
There might be a problem with the motor or control panel. Use a tester to check whether the
panel provides current to the motor or not.
If both the panel and motor run correctly, make sure that the sleeves are mounted correctly and
are not obstructed.
Mixer OD 42 mm
Length 55 mm (chromed part)