7
OPERATION
LEAKS
If a smell of gas becomes apparent, the supply should be turned off at the cylinder
IMMEDIATELY
.
•
Extinguish naked lights including cigarettes and pipes.
•
Do not operate electrical switches.
•
Open all doors and windows to disperse any gas escape.
•
Universal LPG is heavier than air; any gas escaping will therefore collect at low
level. The strong unpleasant smell of gas will enable the general area of the leak to
be detected. Check that the gas is not escaping from an unlit appliance.
•
Never check for leaks with a naked flame, leak investigation should be carried out
using a leak detector spray.
SERVICING
ALL SERVICING MUST BE CARRIED OUT BY AN AUTHORISED PERSON
A pressure test point is fitted to the gas manifold located below the control panel. The
pressure is measured with the front left burner on high flame and with an inlet pressure of
2.75 kPa (Universal LPG).
For service, please contact your authorised local Service Agent giving full details of the
model, serial number and date of purchase.
MANUFACTURED BY:
THETFORD Ltd.
Unit 6 Brookfields Way, Manvers
Rotherham S63 5DL. England.
1. Hob Burner Injector removal/replacement
•
Remove the pan support by pulling up to release it from the spring clips.
•
Remove the appropriate burner cap and skirt.
•
With a 7mm A/F socket, unscrew injector from the bottom of the burner mixing tube.
•
Replace/refit using the reverse procedure.
2. Thermocouple removal/replacement
•
Shut off gas supply and disconnect gas supply pipe from the unit.
•
Remove the spring clip retaining the thermocouple at the burner.
•
From the underside of the hob, remove the appropriate thermocouple from the gas
valve and detach both connections to the shut off switch attached to the hinge
•
Remove the thermocouple.
•
Replace/refit using reverse procedure
•
DO NOT MODIFY THIS APPLIANCE.
•
NO PARTS OTHER THAN THOSE SUPPLIED BY THE MANUFACTURER
SHOULD BE USED ON THIS APPLIANCE.