INTRODUCTION 

 

In your own interest of safety, gas appliances should be installed by competent persons. 

Failure to install the appliance correctly could invalidate any warranty or liability claims. 

This appliance shall be installed in accordance with the manufacturer’s installation 

instructions, local gas fitting regulations, municipal building codes, AS/NZS5601 and any 

other relevant statutory regulations. 

 

Data Label 

The data label is located on the rear panel of the hotplate.  A duplicate data label is 

supplied to adhere to an accessible area next to the appliance. Ensure that the gas supply 

is 

UNIVERSAL LPG

. This appliance is designed for use with Universal LPG and should 

not be converted for use with any other gas. 

 

Ventilation 

Ventilation must be in accordance with AS/NZS5601 Installation Code.  In general, the 

appliance should have adequate ventilation for complete combustion of gas, proper flueing 

and to maintain temperature of immediate surroundings within safe limits. When used 

outdoors, it is recommended that a metal windshield be used. 

 

Location 

Choose a location free of draughts, open doors and clear of combustible materials or other 

fire hazards. The location should ensure convenience of operation and service. Any 

adjoining wall surface situated within 200mm from the edge of any hob burner must be a 

suitable non-combustible material for a height of 150mm for the entire length of the 

hotplate. 

Any combustible construction above the hotplate must be at least 600mm above the top of 

the burner and no construction shall be within 450mm above the top of the burner.  

The surface that the hotplate sits on should be protected by a layer of non-combustible 

material to prevent damage by the heat from the grill. 

 

INSTALLATION 

 

This is a cooking appliance for use in a camping environment and must be used on a firm 

and stable structure in compliance with the location requirements above. 

 

 

 

Gas Connection 

A ¼” (BSP) female gas connection is provided on the back of the appliance.  Refer to the 

diagrams for location of the gas inlet. It is recommended that the appliance be connected 

by copper tubing. For use outdoors a hose assembly complying with AS/NZ1869 may be 

used. Care should be taken to ensure the hose is not exposed to temperatures exceeding 

that for which it is certified and is not subjected to abrasion, kinking or deformation. After 

connection the appliance must be tested for soundness. 

 

This appliance is suitable for use with; 

Universal LPG Only   2.75 Kpa

 

It is important that the regulator should be set to the correct pressure for the type of gas 

being used. Excessive pressure must not be permitted. 

 

 

 

 