7
assembly, request a demonstration of the boiler operation and have operators trained by a professional from the
assembly company. After commissioning, the authorized service technician shall confirm the warranty card for
the electric boiler.
For the electric boiler installation, there needs to be pressured water available on site in order to fill the
system.
♦
Location of the boiler
The electric boiler may be installed in the basic AA5/AB5 environment according to CSN 2000-3 and CSN
33-2000-5:51 ed.3 (temperature range from +5 to 40°C,
humidity depending on the temperature up to max. 85%,
without harmful chemical effects). Suitable for
installation in both residential and non-residential
premises. The boiler shall not be installed in areas with a
bath, in bathrooms, shower rooms in zones 0, 1 and 2
according to CSN 33 2000-7-701 ed.2:2007 and in wash
rooms according to CSN 33 2130 ed.2:2009. In addition
to that, it shall not be installed in zone 3 either if there is
a chance that a jet of water intended for cleaning might
be present. When the boiler is installed in permissible
zones, appropriate protection from electric shock needs
to be ensured according to the aforementioned standard.
There shall be necessary access for operation and service purposes on the installation site.
♦
Suspending the boiler
The electric boiler shall be mounted to a wall using
the suspension bar, wall plugs and screws included
in the delivery. For ideal suspension, the room
needs to have a flat wall with a sufficient load-
bearing capacity. Direct suspension e.g. from
plasterboard structures is not recommended. In case
of installation on a wall with a lower load-bearing
capacity, it is recommended that a construction technician
be consulted. Under the bottom edge of the boiler and
above the upper edge of the casing, a service space of at
least 200mm and 750mm, respectively, needs to be
maintained for the purposes of inspection or replacement of
the heating bodies.