REPLACEMENT THERMOSTATS

Part No.

Wiring Diagram (Figure 8)

XB3-6300T3

Fig. 3

Fig 4

XB3-6276T3

XB3-6252T3

XB3-4250T3

XB3-4230T3

XB3-6225T3B

XB3-4210T3

XB3-6207T3B

XB3-6189T3B

XB3-4150T3B

XB3-4138T3B

XB3-4126T3B

XB2-4100T3B

Fig. 2

-

XB2-4092T3B

XB2-4084T3B

XB2-6085T4A

XB2-6078T4A

XB2-6071T4A

XB1-3047T3B

Fig. 1

-

XB1-3043T3B

XB1-3040T3B

CAUTION

CAUTION. 

Use approved conduit and conduit seals 

as required by hazardous location standards.

E. 

START-UP

For heaters with a tamper-proof thermostat, to set 
temperature, disconnect the power and remove the socket 
head cap screw. Set the thermostat to the desired room 
temperature with a screw driver and replace cap screw.
1. 

For heaters with an externally adjustable thermostat, 
set thermostat to desired temperature by adjusting 
the dial.

NOTE:   The thermostat temperature range is -18° to 40°C (0° 

to 100°F) with an operating differential of 3 to 4°C (5 
to 7°F).

2. 

Install the terminal box cover and tighten securely.

3. 

Check to ensure that all plugs, screws, and covers are 
securely in place.

4. 

Check associated electrical equipment.

5. 

Check that all wall/floor mounting bracket 

connections are tight.

6. 

Turn on the supply power.

WARNING

WARNING. 

To prevent unsafe operation of the 

heater do no exceed the maximum allowable 

ambient operating temperature of 40°C (104°F)

WARNING

WARNING. 

Whenever hazardous materials are 

present, ensure that the terminal housing covers, 
plug, etc., are secured (but not over-tightened) 
before energizing  
the heater.

CAUTION

CAUTION.

 Use supply wires suitable for 105°C 

(221°F). Supply wires are to be fused with 
appropriately sized HRC fusing.

CAUTION

CAUTION. 

All circuits must be in the open position 

before removing junction or terminal box covers.

CAUTION

CAUTION.

 Ensure that no power is connected to 

the equipment prior to making any connections.

Summary of Contents for Norseman XB Series

Page 1: ...ormat shown This symbol indicates a potentially hazardous situation which if not avoided can result in personal injury or damage to the equipment This symbol indicates a potentially hazardous situatio...

Page 2: ...A Pre installation 3 B Installation 3 B 1 General Requiprements 3 B 2 Wall Mounting 4 B 3 Floor Mounting 4 B 4 Thermostat Installation 5 C Wiring 5 D Replacement Thermostats 6 E Start up 6 F Maintenan...

Page 3: ...ch depending on the model could weigh up to 45 kg 100 lbs Otherwise use the brackets supplied to stand the heater on the floor 2 Do not recess the Norseman XB CE heater into the wall Use of the bracke...

Page 4: ...d lock washers Figure 4 Figure 4 Attach heater to mounting brackets B 3 Floor Mounting Step 1 Position heater face down on the floor with terminal box towards the wall Figure 5 page 4 Figure 5 Floor m...

Page 5: ...d in kit number XTKW04483CE Follow the instructions supplied with the kit C WIRING 1 Whenever hazardous materials are present ensure that the terminal housing covers are secure before powering the hea...

Page 6: ...E The thermostat temperature range is 18 to 40 C 0 to 100 F with an operating differential of 3 to 4 C 5 to 7 F 2 Install the terminal box cover and tighten securely 3 Check to ensure that all plugs s...

Page 7: ...administration F MAINTENANCE 1 Periodically inspect the heater installation to ensure that all connections fittings plugs screws covers etc are tight and free of corrosion 2 Check the extrusions of th...

Page 8: ...applies to paint finishes except for manufacturing defects apparent within 30 days from the date of installation The Company neither assumes nor authorizes any person to assume for it any other oblig...