background image

WARRANTY

:

  Under  normal  use  the  Company 

warrants  to  the  purchaser  that  defects  in  material 
or workmanship will be repaired or replaced without 
charge (from date of shipment) for a period of: 

Any claim for warranty must be reported to the sales 
offi ce where the product was purchased for authorized 
repair or replacement within the contract terms. 
Subject  to  State  or  Provincial  law  to  the  contrary,  the 
Company  will  not  be  responsible  for  any  expense  for 

installation, removal from service, transportation, or 

damages  of  any  type  whatsoever,  including  damages 

arising from lack of use, business interruptions, or 
incidental or consequential damages.
The Company cannot anticipate or control the 
conditions of product usage and therefore accepts no 
responsibility for the safe application and suitability 

of  its  products  when  used  alone  or  in  combination 
with other products. Tests for the safe application and 

suitability of the products are the sole responsibility of 
the user.

This  warranty  will  be  void  if,  in  the  judgment  of  the 

Company, the damage, failure or defect is the result of:

 

Vibration, radiation, erosion, corrosion, process 
contamination, abnormal process conditions, 
temperature and pressures, unusual surges or 

pulsation,  fouling,  ordinary  wear  and  tear,  lack  of 

maintenance, incorrectly applied utilities such as 

voltage, air, gas, water, and others or any combination 
of the aforementioned causes not specifi cally allowed 

for in the design conditions 

 

Or, any act or omission by the Purchaser, its agents, 
servants  or  independent  contractors  which  for 

greater certainty, but not so as to limit the generality 
of the foregoing, includes physical, chemical or 
mechanical abuse, accident, improper installation 
of the product, improper storage and handling of the 
product, improper application or the misalignment 
of parts.

No  warranty  applies  to  paint  fi nishes  except  for 
manufacturing defects apparent within 30 days from the 

date of installation.

The Company neither assumes nor authorizes any person to 
assume for it any other obligation or liability in connection 

with the product(s).

The Purchaser agrees that all warranty work required after 
the initial commissioning of the product will be provided 

only if the Company has been paid by the Purchaser in full 

accordance with the terms and conditions of the contract.

The Purchaser agrees that the Company makes no 

warranty  or  guarantee,  express,  implied  or  statutory, 
(including  any  warranty  of  merchantability  or  warranty 
of  fi tness  for  a  particular  purpose)  written  or  oral,  of  the 

Article or incidental labour, except as is expressed or 
contained in the agreement herein.

LIABILITY:

 

Technical data contained in the catalog 

or on the website is subject to change without notice. 

The Company reserves the right to make dimensional 
and other design changes as required. The Purchaser 

acknowledges  the  Company  shall  not  be  obligated 

to modify those articles manufactured before the 
formulation of the changes in design or improvements 
of the products by the Company.
The Company shall not be liable to compensate or 
indemnify the Purchaser, end user or any other party 

against  any  actions,  claims,  liabilities,  injury,  loss, 

loss of use, loss of business, damages, indirect or 

consequential  damages,  demands,  penalties,  fi nes, 
expenses (including legal expenses), costs, obligations 
and causes of action of any kind arising wholly or partly 

from negligence or omission of the user or the misuse, 
incorrect application, unsafe application, incorrect 
storage and handling, incorrect installation, lack of 
maintenance, improper maintenance or improper 
operation of products furnished by the Company.

PLEASE ADHERE TO INSTRUCTIONS IN THIS MANUAL

Failure to do so may be dangerous and may void certain 
provisions of your warranty.

    

84 months - SwitchBlade

®

 Heaters

    

60 months - DC Heaters

    

36 months - DC Control Panels

    

36 months - HELLFIRE Heaters, FEB Heaters

    

12 months - All other Fastrax

®

 Products

For further assistance, please call 1.855.244.3128

Summary of Contents for Fastrax

Page 1: ...g or using the heater Please adhere to instructions published in this manual Failure to do so may be dangerous and may void certain provisions of your warranty Fastrax is a registered trademark of Thermon Copyright 2021 All rights reserved ISO 9001 Energy Management System EMS Installation Operation Manual Rail Thermostat Control Box ArcticSense ...

Page 2: ...heater It detects moisture and senses ambient and rail temperature turning the heater on when it snows and the rail is cold 2 The EMS provides an aggressive retry for heaters equipped with the appropriate remote Flame Safety Relay reset 3 The EMS provides a low temperature cut out feature for use with propane fired heaters that do not have tank heaters and are located in cold environments where th...

Page 3: ... the points and tie duct as shown Select a location shaded from the sun Provide strain relief in the cable by leaving adequate slack as shown to allow for rail pumping Remove the yellow shim washers when installed on 115 lb rail or lighter Loosen the two mounting bolts and attach the rail thermostat to the rail flange by tapping it on with a hammer Once in place tighten mounting bolts to maximize ...

Page 4: ... 5 Replace the cover tighten the four 4 Phillips screws 6 Connect the surge isolator two pin connector with the mating plug located inside the electrical component area hanging immediately under the DSI ...

Page 5: ...al Block 1 terminal 1 or to the ALARM relay terminal 2 1 4 On a Micro heater the signal is available at the ALARM relay terminal 9 NOTE YARDMASTER heaters do not require this connection The aggressive retry feature is integrated into the YARDMASTER controller C 4 Aggressive Retry 1 If the heater you are controlling is equipped with a flame safety relay reset module connect the reset to the appropr...

Page 6: ...quire this feature and the set point can be lowered to the minimum of 55 C 67 F 7 DELAY ON DELAY OFF DIP SWTCHES ON THE BOARD These switches are used to set the DELAY ON and DELAY OFF times for EMS operation The value of the time is calculated by adding the binary code value of the actual switch Minimum step is one minute The values are 1 2 4 8 16 32 64 and 128 and any combination between and up t...

Page 7: ...etal Oxide Varistor Part No 9049 0052 Rail thermostat only 13340 03 Enclosure only 17895 Rail thermostat surge isolator Replacement board only 15948 Rail thermostat jumper 16422 02 Ambient temperature sensor 16426 ArcticSense c w 10 cable 13849 02 ArcticSense head only 13849 03 Rail thermostat c w 40 cable 16442 03 ...

Page 8: ... 16422 03 WITH SURGE PROTECTION ON RAIL TEMP SWITCH GRu 10 APRIL 2000 PRODUCTION RELEASE REF ECN 949 B TB1 1 TB1 2 TB1 3 TB1 4 TB1 5 TB1 6 TB1 7 TB2 1 TB2 2 TB2 3 TB2 4 12 AWG GREEN WIRE 12 AWG GREEN WIRE TB 4 CONNECT POWER GROUND TO GROUND STUD ON ENCLOSURE 13 NOV 2000 C GROUNDING INFORMATION ADDED ECN 1125 PRECIPITATION SENSOR TO GROUND STUD ON ENCLOSURE TO GROUND STUD ON ENCLOSURE D ECN 1122 5 ...

Page 9: ...9 9 Section Running Footer NOTES ...

Page 10: ...10 10 NOTES ...

Page 11: ...11 11 NOTES ...

Page 12: ...ng defects apparent within 30 days from the date of installation The Company neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with the product s The Purchaser agrees that all warranty work required after the initial commissioning of the product will be provided only if the Company has been paid by the Purchaser in full accordance with the t...

Reviews: