background image

                                           Minitherm AQUA 

 

 

2

 

 Safety instructions 

2.1

 

 Proper use  

Minitherm AQUA stove was built in accordance with safety regulations. 

 

EMC (2004/108/EC) 

 

LVD (2006/95/EC) 

 

RoHS 2 (2011/65/EU) 

The stoves fulfill other specified standards and specifications: EN 55014; EN 60335-1; 
EN 55014-2; EN 60335-2-102; EN 61000-3-2; EN 50366; EN 61000-3-3. 
 

Improper use of the stove can result in bodily injury, leading ultimately to the death 
of users and/or others as well as damage to the stove itself or other property. 

2.2

 

Basic principles and operation 

 
The Minitherm pellet stove is a special space heater intended exclusively for domestic 
use and intended only for burning wood pellets of 6mm diameter and 300mm length. 

During operation, the integrated heat exchanger produces hot water which is delivered 
to a central heating system. The integrated pump only switches ON when the preset 

water temperature in the system (50°C) is reached. For normal operation, it is only 
necessary to start the stove and select the  desired power value or temperature. By 
installing the room thermostat, I t is possible to automatically ignite and control the 

stove.  The  pellets  automatically  fall  into  the  burn  pot  and  then  are  ignited  with  an 
electric heating cartridge. Depending on the set value of the power, the pellet conveyor 
automatically  adds  the  required  amount  of  pellets.  The  required  air  supply  for 

combustion into the combustion chamber is controlled. The resulting heat energy in 
the  combustion  chamber  is  supplied  to  the  central  heating.  At  the  end  of  the 
combustion chamber there is an exhaust fan, which releases the flue gases created in 

the chimney. Every day it is recommended to clean the ashes. 
Every 1-2 months or after consumption of approx. 500kg Enplus (A1) pellets a cleaning 
of  the  flue  gas  chamber  and  the  pipe  heat  exchanger  is  required.  The  devices  are 

designed and tested so that they can be installed in homes and have the necessary 
approvals.  For  the  combustion  air  is  needed.  For  this  reason,  the  combined  use  of 

kitchen  exhaust  systems,  and the  ventilation in  the  same  room  with  a  stove is not 
allowed. 
 

The  stove  was  designed  to  burn  wood  pellets.  The  manufacturer  will  accept  no 
responsibility  for  any  damage  resulting  from  improper  use.  Proper  use  includes 
maintaining the installation, operation and maintenance specified by the manufacturer. 

 

Minitherm stove was built in accordance with safety regulations. However, its 
use  can  result  in  the  injury  or  death  of  the  user  and/or  third  part  and  in 

impairments to the stove itself or to other material goods.  
 

 
 

Summary of Contents for Minitherm AQUA

Page 1: ...ThermoFLUX d o o Bage br 3 70101 Jajce Bosnia and Hercegovina Tel Fax 387 30 657 100 www thermoflux ba tfinfo thermoflux ba PELLET STOVE USER AND MAINTENANCE MANUAL...

Page 2: ...2...

Page 3: ...3...

Page 4: ...ng room 10 2 11 Fresh air supply 10 2 12 Safety devices 10 3 General overview 12 3 1 GSM modem 12 3 2 WI Fi module 12 3 3 Technical data 13 4 Installation and commissioning of the stove 14 4 1 Install...

Page 5: ...ove 30 6 1 Ignition 30 6 2 Shutting down of stove 31 6 3 Stove power adjustments 31 6 4 Adjustment of water temperature 32 6 5 Modulation 32 6 6 Cleaning of FIRE POT 33 7 Cleaning and maintenance 34 7...

Page 6: ...he Minitherm AQUA stove 1 3 Technical changes ThermoFLUX continuously develops and improves its stoves The information in this version is correct at the time of going to press All details in this manu...

Page 7: ...nd then are ignited with an electric heating cartridge Depending on the set value of the power the pellet conveyor automatically adds the required amount of pellets The required air supply for combust...

Page 8: ...ed wood pellets and standards Thermo FLUX d o o recommends wood pellets with a diameter of 6mm and a length of 10 30mm Other requirements on the fuel result from either standard O Norm M 7135 DIN plus...

Page 9: ...marked with this symbol may only be done by a qualified electrician WARNING Warning about a dangerous location Work on areas marked with this symbol can lead to serious injuries or to extensive materi...

Page 10: ...made according to current regulations especially regarding fire protection Storage of flammable materials cleaning agents and similar materials must not be stored in the boiler room The stove should...

Page 11: ...itherm AQUA 11 Safety limit Thermostat STB intervenes by breaking the circuit in the stove automatically stops motor of the auger and exhaust gasses fan if the stove temperature reaches the limit of 9...

Page 12: ...nternet Compatible with Android IOS and Windows devices The user can have full control over boiler via the application The Minitherm Aqua stove is compact and requires less than 1m2 for installation s...

Page 13: ...temperature o C 80 9 Max working pressure bar 2 5 10 Height to center of flue pipe mm 198 5 11 Depth mm 575 12 Width mm 480 13 Height mm 945 14 Color red black 15 Flue pipe diameter mm 80 16 Inlet ou...

Page 14: ...zed service for the first start must control the functioning of the stove at least during one full operating cycle In some countries it is obligatoy for first commissioning to be controled and autoriz...

Page 15: ...ich would enable the cleaning of inner parts especially the horizontal parts Smoke pipe should be installed fixed It would be good to leave safety gates that could do the Minitherm r cleaning especial...

Page 16: ...ion can be achieved in different ways One way is to easily open the cleaning door We recommend to install the draft regulator The pellet stove can not be connected To the chimney or the flue pipe to w...

Page 17: ...with revision or a knee after the chimney outlet and a piece of flue pipe of a length of min 0 5m and then connect the stove to the chimney It is not recommended to connect directly between the stove...

Page 18: ...Minitherm AQUA 18 4 3 Hydraulic schemes for connection...

Page 19: ...ssibility to place the room thermostat in one room and does not need to be in the same room where the pellet stove is Operation of the stove with an external thermostat connected to the room thermosta...

Page 20: ...tions Button Description 1 Increasing temperature and program functions adjusting days time 2 Decreasing temperature and program functions adjusting days time 3 Changing accepting program 4 ON OFF pro...

Page 21: ...ciple of the stove operation is very simple When button for start is pressed stove goes into IGNITION MODE START is displayed and after that PELLET IGNITION Usually this phase lasts for 5 15 minutes d...

Page 22: ...Minitherm AQUA 22 5 3 Schematic representation of the menu control By pressing button SET we enter general menu...

Page 23: ...Minitherm AQUA 23...

Page 24: ...Minitherm AQUA 24 5 3 1 Clock adjustments Clock adjustments can be done on following way...

Page 25: ...ies to all days in the week Scheme 2 WEEK PROGRAM in this mode we can set 4 four different times for ignition and shutting down In this mode we can choose day in the week MON SUN in which we want stov...

Page 26: ...Minitherm AQUA 26 Flow chart 2 Flow chart 3 Flow chart 4...

Page 27: ...talled sensor for air temperature Connection for room thermostat is delivered overbridged which means that contact is closed 1 FUNCTION STAND BY SET ON In the case that function STAND BY is activated...

Page 28: ...king power will change to lowest Stove will shut down only if temperature of the air in the system is 80 degrees C and on display is written WAITING COOLING Stove will start again when temperature in...

Page 29: ...stove On display information is randomly changed about air temperature in the stove flue gasess temperature fan RPM etc To enter this option press SET after that with buttons 5 or 6 we choose MENU 07...

Page 30: ...g things needs to be checked Silo needs to be filled with pellet Silo doors needs to be closed Combustion chamber basket needs to be cleaned Ash pot needs to be clean All doors on stove needs to be cl...

Page 31: ...Stove power adjustments During working phase it is neccesary to set working power in which we want stove to work Adjustments of the working power is possible in the range from 1 5 and selection of des...

Page 32: ...k and changes power to lowest Modulation starts 4 C below set temperature EXAMPLE We have adjusted water temperature on 73 C and power 5 regulation will work in power 4 when temperature is 70 C on 71...

Page 33: ...n basket fire pot after certain time This phase is shown on display and work of the stove is set to lower power and suction fan is working on maximun for certain period of time as set in the factory W...

Page 34: ...ion Using safety gloves take the firebox out and empty its content into a fire resistant container Clean the holes in the firebox with an appropriate screwdriver if neded Put the firebox back onto the...

Page 35: ...xchange tubes before cleaning of ash pot and braizer basket Turn the stove off and wait until it has been cooled Remove the cover behind door 1 remove two nuts 2 and with the steel brush clean the pip...

Page 36: ...as chamber Clean the sediments out of the tube heat exchanger using the vacuum cleaner Check if there is any ash left in the firebox or in the ash pan and clean them in accordance with the instruction...

Page 37: ...illing A foreign object stuck dosage spiral clean Poor quality pellets wet pellet long pellets dust into pellets change the type of pellets Pellet igniter is defective replace it Contact Service Resta...

Page 38: ...Minitherm AQUA 38 BLACK OUT The stove is out of power Reset alarm and start again...

Page 39: ...disposed on landfills for metal stove cover metal sheets feeding system except motor braizer basket Electronic components can be recycled Glass glass wool and plastic parts can be recycled on landfil...

Page 40: ...be done by authorised service or person authorised by ThermoFLUX or authorised importer distributor Stove must work in accordance with terms and conditions given in this manual Stove needs to be insta...

Page 41: ...Minitherm AQUA 41 11 EU Label...

Page 42: ...Minitherm AQUA 42...

Page 43: ...Minitherm AQUA 43...

Page 44: ...Minitherm AQUA 44 User manual MINITHERM LCD ENG 2019 ThermoFLUX d o o Bage br 3 Jajce Bosnia and Herzegovina Tel fax 387 30 657 100 www thermoflux ba...