background image

 

 

31 

 

 

6.3.1

 

Clock adjustments 

Clock adjustments can be done on following way: 

 

Summary of Contents for INTERIO

Page 1: ...ThermoFLUX d o o Bage br 3 70101 Jajce Bosnia and Hercegovina Tel Fax 387 30 657 100 www thermoflux ba tfinfo thermoflux ba PELLET STOVE USER AND MAINTENANCE MANUAL...

Page 2: ......

Page 3: ...nd safety instructions Always keep the instructions an place near the stove Due to constant improvement and development of our products some pictures or illustrations in this guide may vary IMPORTANT...

Page 4: ...1 1 Basic principles 15 3 1 2 Handling with the stove 15 3 1 3 Use of the stove 15 3 1 4 Changes on the stove 15 3 2 Pellets that can be used in boilers 16 3 2 1 What is pellet 16 3 2 2 Recommended wo...

Page 5: ...6 3 5 2 STAND BY mode with room thermostat connected 35 6 3 6 Option Buzzer 35 6 3 7 Filling of spiral dispenser 36 6 3 8 STATE OF THE STOVE 36 6 3 9 Technical settings 36 6 3 10 FUEL TYPE 36 7 Ignit...

Page 6: ...5...

Page 7: ...lt in deviation from the technical details and illustrations shown in this manual 1 3 Copyright It is forbidden to copy and download content from this manual Required written permission by ThermoFLUX...

Page 8: ...with an electric heating cartridge Depending on the set value of the power the pellet conveyor automatically adds the required amount of pellets The required air supply for combustion into the combust...

Page 9: ...on locations marked with this symbol can cause injuries CAUTION Hot surfaces Work on locations marked with this symbol can lead to burns CAUTION Risk of flammability Work on locations marked with this...

Page 10: ...of the stove flue gas pipes and heating pipes can cause severe burns Use gloves when working with the stove Maintain the stove only according to the instructions Insulate the flue pipes and avoid poss...

Page 11: ...se the door Open all available valves on the radiators distribution boxes If the temperature in the system is not decreasing call the authorized service center 1 7 2 Smoke Flue gases can cause poisoni...

Page 12: ...nstall and use the stove for central heating use The stove is delivered with the accompanying material Power cable Key Manual Guarantee Additional equipment which can be used is not supplied with an o...

Page 13: ...nd Windovs devices The user can have full control over the boiler via the application enable disable change the power of work change the temperature and to program delayed ignition and shutdown times...

Page 14: ...13...

Page 15: ...pressure bar 2 5 2 5 11 Height to center of flue pipe mm 305 305 12 Depth mm 650 650 13 Width mm 630 630 14 Height mm 1080 1080 15 Avaliable colors red beige white red beige white 16 Flue pipe diamet...

Page 16: ...damage caused by improper handling Proper use implies maintenance of the installed stove operation and maintenance conditions prescribed by the manufacturer The user can enter or change only those val...

Page 17: ...It is not allowed to use any additives or glue during the pellet production The pellet contains a minimal amount of moisture and ash and has a maximum energy value for the type of wood from which the...

Page 18: ...by children without proper supervision 3 4 Local standards All local laws must be respected during installation as well as standards and norms that are in force in the country where the stove is inst...

Page 19: ...ntrol Intervenes directly turns off the stove until it cools down and shows an error on the display screen in case of a failure of exhaust fan malfunction of the dispenser engine or failure of the ign...

Page 20: ...ast during one complete work cycle In some countries it is obligatoy for first commissioning to be controled and autorizied by chimney sweep or a person authorized to control Risk of material and phys...

Page 21: ...ealing In any case materials that could potentially catch fire e g wooden planks beams cloth should be adequately protected with non combustible material For the sake of parity of dimensions chimneys...

Page 22: ...th a maximum of two exhaust pipes For stove operation a constant negative pressure is required At reduced power the flue gas temperature is low and condensation may occur It is therefore important tha...

Page 23: ...hen connecting the pellet stove to the chimney smoke pipes with a diameter of 80mm and temperature resistant gakets must be used It is recommended to install a T piece with revision or a knee after th...

Page 24: ...23 5 Connection 5 1 Hydraulic schemes for connection...

Page 25: ...24 5 2 Electrical wiring diagram...

Page 26: ...e room thermostat in one room and does not need to be in the same room where the pellet stove is Operation of the stove with an external thermostat connected to the room thermostat connection may diff...

Page 27: ...tton Description 1 Increasing temperature and program functions adjusting days time 2 Decreasing temperature and program functions adjusting days time 3 Changing accepting program 4 ON OFF program exi...

Page 28: ...or decrease heating by automatic adjustment of power If there is a need to increase power this is registered by regulation and regulation gives a signal to increase power by adding more pellet as wel...

Page 29: ...starts to ignite pellet and suction fan is on and is making necessary underpressure needed for combustion When temperature sensor for flue gasses detects that temperature in the chimney has reached n...

Page 30: ...29 6 3 Schematic representation of the menu control By pressing button SET we enter general menu...

Page 31: ...30...

Page 32: ...31 6 3 1 Clock adjustments Clock adjustments can be done on following way...

Page 33: ...r ignition and shutting down of the stove This applies to all days in the week Scheme 2 2 WEEK PROGRAM in this mode we can set 4 four different times for ignition and shutting down In this mode we can...

Page 34: ...33 Sheme 2 Sheme 3 Sheme 4...

Page 35: ...ode is activated by pressing button SET and afterwards by pressing buttons 5 and 6 we choose desired item in the MENU 04 STAND BY MODE By pressing SET we are opening options ON or OF choosed by pressi...

Page 36: ...ow contact closed temperature needs to be reached stove will start ignition and on display is written tON Remark Stove functioning primarily depends on temperature of the water inside of stove and fac...

Page 37: ...possibilty that there are some leftovers from pellet in it while spiral dispenser was filled Combustion chamber needs to be empty and then ignition process can be initiated 6 3 8 STATE OF THE STOVE St...

Page 38: ...needs to be checked Silo needs to be filled with pellet Silo doors needs to be closed Combustion chamber basket needs to be cleaned Ash pot needs to be clean All doors on stove needs to be closed Sto...

Page 39: ...NAL Suction fan is working on maximum feeding of pellet is stopped 7 3 Stove power adjustments During working phase it is neccesary to set working power in which we want stove to work Adjustments of t...

Page 40: ...factory settings and it is not possible to set lower or higher temperature then above mentioned 7 5 Modulation When water temperature in stove is near to set value regulation begins to modulate its w...

Page 41: ...t process of ignition again 7 6 Cleaning of FIRE POT During its work stove has set timer for cleaning of combustion basket fire pot after certain time This phase is shown on display and work of the st...

Page 42: ...ficient combustion Using safety gloves take the firebox out and empty its content into a fire resistant container Clean the holes in the firebox with an appropriate screwdriver if neded Put the firebo...

Page 43: ...eat exchange tubes before celaning of ash pot and braizer basket 1 Turn the stove off and wait until it has been cooled 2 Remove the cover by easy pull up 3 Under the cover are two plates 14 Interio h...

Page 44: ...43 Pulling up and down clean the tubular exchanger of the ash deposit 4 In the interior of the firebox behind is the cover of the flue gas chamber fixed with butterfly screws...

Page 45: ...44 5 Remove the cover and with a vacuum cleaner remove accumulated ash also the ash deposits from the fan blades 6 After cleaning put all the parts back to the place where they were...

Page 46: ...e replace it Contact Service Restart the boiler NO PELET During operation of the boiler flue gas temperature has decreased below the permitted values No pellets in the silo fill the pellets in a silo...

Page 47: ...er temperature exceeded 95 C Wait for the boiler to cool down and then unscrew the plastic cap and suitable tool to reset the switch It is possible that the pump is is out of service and there is no w...

Page 48: ...sed on landfills for metal stove cover metal sheets feeding system except motor braizer basket Electronic components can be recycled Glass glass wool and plastic parts can be recycled on landfills Mot...

Page 49: ...y authorised service or person authorised by ThermoFLUX or authorised importer distributor Stove must work in accordance with terms and conditions given in this manual Stove needs to be instaled in ac...

Page 50: ...49...

Page 51: ...50 ThermoFLUX d o o Bage br 3 Jajce Bosnia and Herzegovina Tel fax 387 30 657 100 www thermoflux ba 2018...