background image

12  |   Operation

SpeedVac™ SPD130DLX

Rotors

Traditional Rotors for SPD130DLX Vacuum Concentrator

Accessories

Sample Format 
Type

Working 
Volumes (ml)

Number  Description

Traditional Rotor 
Model

MICROCENTRIFUGE 
TUBES

1.2 - 1.6

40

1.5 -2.0 ml

RH40-11

1.2 - 1.6

64

1.5 -2.0 ml

RH64-11

1.2 - 1.6

120

1.5 -2.0 ml

RH120-11

3.5

10

17 X 60 mm   (5 ml)

RH10-15

GLASS AND PLASTIC 
TUBES

0.3

100

0.4 ml (96 X 50 mm)

RH100-6

0.3

100

0.5 ml (8 x 29)

RH100-8

4

40

1.5 - 20 ml (12 x 75mm)

RH40-12

4

72

12 X 75mm

RH72-12

8

32

13 X 100mm

RH32-13

15

8

17.5 X 102 mm, 15ml Corex tubes

RH8-17.5

10

8

18 X 100 mm, 17 x 95, 16 x 100

RH8-18

CENTRIFUGE TUBES

12

10

15ml conical (16 x 120 mm)

RH10-15

40

6

50ml conical (28 x 115 mm)

RH6-50

FLASKS

80

4

100 ml pear shaped flask

RH4-100

VIALS

2

60

12 x 32 mm, 12 x 40 mm

RH60-12-40

3

24

1 dram vials, 15 x 45 mm (4ml)

RH24-15

2.4,  4

12

20 x 47 mm, 20 x 60 mm

RH12-20

5.6

24

18 x 52 mm scintillation vial

RH24-18

16

12

28 x 60 mm, 20ml scintillation vial

RH12-28

MICROWELL PLATES

2

Shallow well plates

RHDW2MP

6

Shallow well plates

RHSW6MP

Part No.

Description

GCF400

Glass condensation flask

FC400

Flask cover for GCF400

145-6012-00

Foam insulating ring 

SCC1*

CryoCool

®

 heat transfer fluid (1 liter) 

Summary of Contents for SpeedVac SPD130DLX

Page 1: ...Installation and Operation 80302133 Revision A July 2018 SpeedVac SPD130DLX Vacuum Concentrator...

Page 2: ...mo Fisher Scientific Inc provides this document to its customers with a product purchase to use in the product operation This document is copyright protected and any reproduction of the whole or any p...

Page 3: ...4 Installation of SPD130DLX 4 Operation 5 Description Of Control Panel 5 Manual Run 7 Auto Run Time 8 Auto Run Vacuum 8 Drying Rate 8 Preset Program Settings 9 Exporting Live Run Data 9 HyperTerminal...

Page 4: ...th dual timer for automatic or manual control of run conditions it also features preset and user defined programs which enable user to retrieve and store application protocols for future use The compa...

Page 5: ...dicates extreme low temperatures and high risk of frostbite Do not touch bare metal or samples with unprotected body parts This symbol indicates possible pinch points which may cause personal injury T...

Page 6: ...tive Power 115 VAC 60 Hz 6 amps 230 VAC 50 Hz 3 amps Vacuum Chamber TEFLON coated chemical resistant aluminum casting Cover Heated cover with radiant lamps includes a safety interlock Induction Motor...

Page 7: ...130DLX units configured for 230 VAC 50 Hz should be plugged into a circuit rated for at least 3 amps Note Do not use any detachable power cord that is not adequately rated for the unit Installation of...

Page 8: ...hand to ensure alignment of the pin with the groove Secure the assembly by screwing the retaining knob into the drive shaft above the rotor Tighten it firmly but not excessively Description Of Contro...

Page 9: ...meters is shown by the corresponding indicator that is illuminated 8 Minus Decrements the value of the selected parameter 9 Plus Increments the value of the selected parameter 10 View During a run pre...

Page 10: ...tor with the supplied knob hand tight Close cover 10 Pre heat may be selected at this time to apply a 45 C heat to the chamber 11 Press the Manual Run button The cover locks and the lid locker indicat...

Page 11: ...and remove samples Auto Run Vacuum 1 Refer to the Manual Run section for start up 2 To execute an Automatic Vacuum run execute the following steps a Select the Run Type as Vac b Use the Select button...

Page 12: ...C The heat time is expressed as a 3 digit integer in minutes or CCC for continuous heating The runtime is expressed as a 3 digit integer in minutes The vacuum pressure is represented as a floating poi...

Page 13: ...id stay mechanism that will assist the user in opening and closing the cover of the unit It will secure the lid and maintain it open allowing the user to operate the unit with both hands Figure 3 Lid...

Page 14: ...cid Ammonium hydroxide n butyl alcohol Chloroform Cyclohexane DCM Ethyl acetate Ethanol Ethyl ether n Hexane n Heptane Isopropyl alcohol Isobutyl alcohol Methanol Petroleum ether n propyl alcohol Pyri...

Page 15: ...0mm RH32 13 15 8 17 5 X 102 mm 15ml Corex tubes RH8 17 5 10 8 18 X 100 mm 17 x 95 16 x 100 RH8 18 CENTRIFUGE TUBES 12 10 15ml conical 16 x 120 mm RH10 15 40 6 50ml conical 28 x 115 mm RH6 50 FLASKS 80...

Page 16: ...neutralizing solution for Oligo Preps Used on UVS850DDA only SCT120 Chemical trap order cartridges separately DTK120R Chemical trap kit for radioactivity compatible with all Thermo vacuum concentrator...

Page 17: ...Pump ANT100 Exhaust recovery Post trap Vacuum Tubing From Cold Trap to Back of SPD130DLX UVS850DDA Vacuum Tubing From Back of SPD130DLX To Cold Trap SpeedVac Concentrator SPD130DLX Vacuum Tubing RVT45...

Page 18: ...MA number issued by Thermo Costs of shipping the unit are not covered under warranty The warranty obliges you to follow the precautions in this manual When returning apparatus that may contain hazardo...

Page 19: ...riciclato tramite queste medesime Ulteriori informazioni sulla conformit di Thermo Fisher Scientific con queste Direttive l elenco delle ditte di riciclaggio nel Vostro paese e informazioni sui prodo...

Page 20: ...30 France 33 2 2803 2180 33 2 2803 2180 Germany 0800 1 536 376 49 6184 90 6000 0800 1 536 376 Italy 32 02 95059 552 39 02 95059 552 432 254 375 Netherlands 31 76 579 55 55 31 76 571 4440 Nordic Baltic...

Reviews: