4.4

 

  Electrical connection 

This heater is suitable for 230-240V. 

Please observe national standards, the regulations of your local electricity supply company as well as 
data on the rating label.

 

 
Electrical safety! 

The ELEX 

euro

 convective panel heaters are IP24 protected against splashing water.  In humid areas 

such as bathrooms, the power socket must be installed at least 25cm above floor level. 

Note the details on the rating plate! 

The voltage supply must match the requirements on the rating plate. The supply cable must be 
correctly sized. The heater must be connected to a socket outlet or permanent terminal box at least 
10 cm to one side of the heater. 

 
Please note in general: 

Where the ELEX 

euro

 convective panel heater is fitted in a room with a bath or shower, ensure the 

safety zone defined in IEE Regulations is applied in accordance with the details on the rating plate. 

 
To avoid hazards, if the power cord of the appliance exhibits visible damage it must be 
replaced by the manufacturer or his service agent or a qualified electrician.

 

 

4.5  Safety Notes 

The ELEX 

euro

 convective panel heater is equipped with a safety cut-out that switches the heater off 

if it overheats.   
Once the heater has switched off due to overheating, remove the cause of the fault, e. g. blocked air 
grids.  When the heater has cooled down for several minutes it will restart automatically. If the heater 
then cuts off again, switch off the heater and call an authorized serviceman. 
 

5. Warranty 

The below Warranty Terms and Conditions apply for

 New Zealand and Australia only.

 For 

international warranty please refer to international warranty terms and conditions. 
 

Thermofilm warrants to the original owner that ELEX 

euro

 products will be free from defects in 

materials and workmanship for a period of 24 months for residential use from the date of purchase in 
accordance with the following warranty terms and conditions. For commercial use warranty is 12 
months. 
 
Provision of this warranty is subject to:  

 

The ELEX 

euro

 product must be installed in accordance with the Installation Instructions and 

relevant electrical standards and codes.  

 

The ELEX 

euro

 product must be maintained and cleaned according to instructions detailed in 

the Installation Manual. 

 

There is no warranty expressed or implied with regard to capacity requirements. The selection of 

the unit or units depends entirely upon the system design and capacities as determined by the 
purchaser.  

 

The customer has not repaired, opened or altered the product in any unauthorised manner. 

 

This warranty excludes damage to the product or components arising from circumstances outside 

the control of Thermofilm, including, but not limited to, where the product is not used for intended 
purpose; where the product has been rectified in any way; incorrect installation; incorrect power 
supply; damaged caused during delivery; misapplication, misuse, abuse, vandalism, lack of maintenance 

Summary of Contents for ELEX euro 1000

Page 1: ...Panel Guide 3 2 Switching on the Unit 3 3 Programming the Timer 3 3 1 Programming the Clock 3 3 2 Setting the Temperature 3 3 3 Selecting the Constant Heating Operation 3 3 4 Selecting the Constant Fr...

Page 2: ...le Do not immerse in liquid or allow liquid into the interior of the appliance as this could create an electric shock hazard Do not reach for an appliance that has fallen into water Switch off at supp...

Page 3: ...nd a self set weekly operation programme 3 1 Control Panel Guide 1 Main Power Switch 1 0 ON OFF 2 Unit Power button ON OFF 3 Copy button 4 Down button 5 Up button 6 Temperature button 7 Timer button 8...

Page 4: ...again to complete the timer setting The control panel will show the current time and the unit will operate under the default programme of CO Constant Heating Operation 3 3 2 Setting the temperature P...

Page 5: ...ogramme to start another weekday for example the Tuesday press the timer button consecutively until the symbol surrounds T Tuesday on the screen Selecting Times for a Full 24 hour Day Note The zone fo...

Page 6: ...work for another day or days in the week the programme can be copied onto the selected day For example you have just created a 24 hour programme for Monday and you wish to copy this Monday programme...

Page 7: ...of a mains power failure or long period when the heater has been turned off the timer and SS programme must be reset by the user All other pre set programs and default temperatures will be saved 3 3 9...

Page 8: ...or wheel set These units are suitable for heating enclosed indoor rooms such as bedrooms studies offices living areas and bathrooms ATTENTION The installation electrical connection and first operation...

Page 9: ...et is oriented centrally See RHS diagram Step 1 Loosen the locking plate screw and rotate the locking plate out of the fixing slot See RHS images Then remove the mounting bracket from the heater Step...

Page 10: ...g blocked air grids When the heater has cooled down for several minutes it will restart automatically If the heater then cuts off again switch off the heater and call an authorized serviceman 5 Warran...

Page 11: ...floods abnormal weather conditions delayed supply of components Should products be determined as damaged on arrival immediately notify the transport company of the condition and have them noted on the...

Reviews: