2.   Specification Data 

Model 

ELEX

 

eco

 

1000

 

ELEX 

eco

 1500 

ELEX

 eco

 2000 

ELEX 

eco

 2400 

Power (W) 

1000W 

1500W 

2000W 

2400W 

Voltage (V) 

240V~50Hz 

240V~50Hz 

240V~50Hz 

240V~50Hz 

Dimension (mm) 

420 x 440 x 105 

580 x 440 x 105 

740 x 440 x 105 

1000 x 440 x 105 

 

3.   Operating Instructions 

The control panel features a 30min / 60min / 90min push button timer with digital countdown timer 
display. This heater is designed to heat at an economical preset temperature of 21°C for the chosen 

time of 30min, 60min or 90min. 

 

 

 

3.1  Control Panel Guide 

  

1

 -  Main Power Switch (1/ 0 – ON / OFF) 

  

2

 -  Unit Power button (ON / OFF) 

  

3

 -  30 minute push button timer 

  

-  60 minute push button timer 

  

5

 -  90 minute push button timer 

  

6

 -  LED screen 

  7

 -  Power On light 

 

3.2   Switching on the Unit 

Press the main power switch (

1

) on the right hand side of panel.   Press the 

 button (

2

) on the 

control panel.  This turns the unit ON, and the LCD screen (

6

) will illuminate displaying  

 
Note: The red “ON” indicator light (

7

) illuminates when the heating element is operating. 

 

Upon first use, the heater may give off some fumes (this is normal)

.  

Ensure that the room is ventilated (for example, open a window). 

 
3.3  Preset Temperature 

The preset temperature setting for the ELEX 

eco

 heater is 21°C, and this cannot be altered. 

 

POWER 

Summary of Contents for ELEX eco 2400

Page 1: ... 3 1 Control Panel Guide 3 2 Switching on the Unit 3 3 Preset Temperature 3 4 Setting the 30min 60min 90min Timer 3 4 1 Setting the 30min Push Button Timer Programme 3 4 2 Setting the 60min Push Button Timer Programme 3 4 3 Setting the 90min Push Button Timer Programme 3 4 4 Changing to another Timer Setting in Mid Programme 3 5 Locking the Control Panel 3 6 Unlocking the Control Panel 3 7 Safety ...

Page 2: ...revent overload and blown fuses do not plug other appliances into the same power outlet receptacle Do not immerse in liquid or allow liquid into the interior of the appliance as this could create an electric shock hazard Do not reach for an appliance that has fallen into water Switch off at supply and unplug immediately Do not operate appliance with wet hands Always ensure that hands are dry befor...

Page 3: ...et temperature of 21 C for the chosen time of 30min 60min or 90min 3 1 Control Panel Guide 1 Main Power Switch 1 0 ON OFF 2 Unit Power button ON OFF 3 30 minute push button timer 4 60 minute push button timer 5 90 minute push button timer 6 LED screen 7 Power On light 3 2 Switching on the Unit Press the main power switch 1 on the right hand side of panel Press the button 2 on the control panel Thi...

Page 4: ...es the heater will turn off 3 4 3 Setting the 90min Push Button Timer Programme Press the button the display will be The red ON indicator light illuminates the heater starts working and produces heat at the 21 C preset temperature for 90 minutes The digital display will countdown the time remaining from 90 minutes to 00 minutes Once the digital display reaches the heater will turn off 3 4 4 Changi...

Page 5: ...te vicinity of pipes or containers which carry or contain combustible or potentially explosive substances For this reason the minimum clearance intervals must not be undercut In workshops or other areas in which the odor of waste gases oil petrol etc might occur or in which work is carried out involving solvents and chemicals there is a risk of sustained odor burdens being engendered and possibly ...

Page 6: ...gs are not adversely affected The ELEX eco convective panel heater must not be installed immediately below a wall socket The heater must be connected to a socket outlet or permanent terminal box at least 10cm to one side of the heater If the heater is installed in the Bathroom or in humid area the socket outlet or permanent terminal box must conform to the IP24 requirement The ELEX eco convective ...

Page 7: ...ctive panel heaters are IP24 protected against splashing water In humid areas such as bathrooms the power socket must be installed at least 25cm above floor level Note the details on the rating plate The voltage supply must match the requirements on the rating plate The supply cable must be correctly sized The heater must be connected to a socket outlet or permanent terminal box at least 10 cm to ...

Page 8: ...LACEMENT WARRANTY To claim for Warranty please retain your receipt as proof of purchase and return the faulty heater to the place you purchased it Warranty does not apply to heaters which have been misused or used in conditions other than those for which they were intended for Nor will it apply in the event of damage or accident resulting from negligence lack of care or maintenance or if the heate...