Manual flame height adjustment using various modes 
 

Press the 

high 

button to switch the fire on or to adjust the flame height upwards; use the 

low 

button to 

lower the flame height or until only the pilot light is burning. The manual control function overrides all 
functions. Simply press the 

high or low 

 button in order to activate the manual control function. The 

trans-

mit 

symbol will then appear at the top left of the display. Just press the 

timer 

or 

auto 

button to adjust set-

tings in the timer or auto function. When the auto function is activated by pressing the 

auto 

button, the set 

temperature will appear in the display for a short time, before changing to the ambient temperature. There 
is only one adjustment option for the temperature (setting auto mode, see paragraph 2) for both heating pe-
riods 

P1 

*

 

and 

P2 

*

 

and the same applies

 

in the timer mode. When the timer mode has been activated, the 

auto 

button can be pressed to check the temperature setting and the 

timer 

button can then be pressed again 

to return to the timer mode. When the timer mode is in the  

)

  position ( “off” outside the heating period), 

the gas valve will now be turned back to the pilot light setting. 

 
 
Changing the battery 
 

When the text 

BAT

 appears in the top right of the display, replace the battery with a new one. 

Remote control : 1x 9V block (alkaline recommended) 
Receiver : 4x AA 1.5V (alkaline recommended) 

 
NB 

Before settings are adjusted by means of  the auto and timer modes, press one of the 

high/low 

buttons in 

order to see whether the 

transmit 

symbol appears in the top left of the display, and the green 

LED 

on the 

receiver (See Page 14 diagram 6-F1). This makes it possible to check whether the whole remote control/
receiver combination is working properly. 
 
The temperature is controlled by the activity of the gas block motor in adjusting the appropriate flame 
height for a specific length of time. Flame height is determined by variables such as the size of the room, 
capacity of the fire, battery voltage, etc. The remote control measures how quickly the room temperature 
increases when the fire is on and activates the gas block motor for a longer or shorter time during the fol-
lowing heating period (for better flame height adjustment). After a number of periods, the fire will keep on 
burning at “low”, or between the “low” period and “off”, when the heat is sufficient to maintain the pre-set 
heat. 

 
Connections 

 
The right-angled connectors (D) of the receiver wires must be attached to the flat 6.3 mm & 4.8 mm con-
nections linked to the motor. The model with thermostat and timer must only be used in combination with 
the GV 34 gas block or a modified (motorized)  GV 36 gas block, and then only with a cover with micro 
switch connection. The connectors (P) must be coupled to the flat 2.7 mm connectors on the micro switch 
for this purpose. 
 

Technical specifications 

 
Radiographic Transmission:    Frequency: ON 40.5 kHz, OFF 40 kHz / Range: 0.5…10m 
Ambient temperature           :   Transmitter & Receiver: max. 60ºC / Connecting wires: max.180ºC 

Summary of Contents for Apertura series

Page 1: ...Page 1 OPERATING AND INSTALLATION INSTRUCTIONS Apertura line...

Page 2: ...tinguishing Warning Maintenance 3 Preparations for installing the Apertura Page 6 4 Installation instructions for the Apertura with concentric duct connection Page 7 General instructions Components of...

Page 3: ...e appliance must be checked by the installer for gas tightness to gas and combustion products and the correct operation of the various components and functions In addition the flue system and the outl...

Page 4: ...but this can also be done by pushing the timer button Setting the required temperature Press the auto button until the display starts to flash Use the high low buttons to set the required tempera ture...

Page 5: ...e settings are adjusted by means of the auto and timer modes press one of the high low buttons in order to see whether the transmit symbol appears in the top left of the display and the green LED on t...

Page 6: ...re extinguishing the appliance completely Now turn knob A1 to the right as far as it will go to position push the knob in and then turn it to position Warning After extinguishing the pilot light wait...

Page 7: ...ead Section 5 Concentric duct system on page 8 before installing the ap pliance in connection with the necessity of fitting the restriction sheet First dismantle Front 11 12 or 13 depending on the ver...

Page 8: ...terial See Page 15 A Position the log set as shown on Page 15 Do this with care since soot may be formed if the log set is wrongly positioned You finally position and fit the glass the glazing beads a...

Page 9: ...tive length per bend 1 metre until the maximum pipe length of 12 metres is reached including bends but excluding vertical terminal The minimum length is 3 metres The outlet may oc cupy any position on...

Page 10: ...allation of the vertical terminal The outlet can be placed at any arbitrary position on the roof surface inlet and outlet in identical pressure areas but must comply with the current regulations Use a...

Page 11: ...ry I3p b I3p b I3p b I3p b I3p b I3p b Country NL SP FR BE DE GB Pre Pressure MBAR 50 30 37 30 37 30 37 30 50 50 37 30 Burner Pressure MBAR 36 29 4 36 29 4 36 29 4 36 29 4 36 29 4 36 29 4 Injection Bo...

Page 12: ...Page 12 1...

Page 13: ...Page 13 5 2 4 3...

Page 14: ...Page 14 G25 G20 30 31 7 49 G25 55 G20 30 31 6...

Page 15: ...Page 15 A...

Page 16: ...Page 16 8 9 10 11 12...

Page 17: ...Page 17...

Page 18: ...Page 18 A E B C F I H G K L J M N O P...

Page 19: ...KET 12965024 12965524 D NOT AVAILABLE E CONCENTRIC BEND 90 12965014 12965514 F WALL BAND ADJUSTABLE 12965026 G ADJUSTABLE LENGHT 250 12965006 H FLAT ROOF PLATE 12965020 12965520 I LOCKING BAND 1296503...

Page 20: ...Page 20...

Page 21: ...liance is fitted with insulated covering one of the following materials should only be used Loose white insulation wool heat resistant to 1000 C Rocktherm 180 012 insulation wool 700 C from Rockwool o...

Page 22: ...ot covered by the guarantee Defects caused by inexpert assembly and or treatment Costs of transport assembly and dismantling Glazing fire gratings refractory stones flue gas baffle plates heat shields...

Reviews: