5

40.021.119 - rev. 00 - 2019

English

IMAC 4000 GAS US

Contents

Safety instructions

Introduction

Preparations

Use

Maintenance

Faults

Spare parts

Technical information

Installing accessories

Foreword

This manual contains the instructions for use of

the convector heaters shown on the cover. The

information in this manual is important for the

correct and safe operation of the convector

heater.

Identification of the product (Fig. 1)

The identification plate is mounted on the side of

the convector heater. The identification plate

contains the following data:

A   

Revolutions fan

B    

Total current

C    

Air volume

D    

Air Volume

E    

Max. resistance outlet

F    

Voltage

G   

Herz

H   

Net capacity (Hi)

Net capacity (Hi)

J  

Fuel consumption NG

K  

Fuel consumption NG

L  

Burner manifold pressure

M  

Inlet burner pressure propane

N  

Inlet burner pressure natural gas

O Weight

Fabrication year

Product code

Serial number

Service and technical support

For information about the convector heater,

please contact your dealer of the manufacturer.

Make sure you have the following data at hand:

type and serial number of the convector heater.

Warranty and liability

For warranty and liability, see general warranty

regulations.

Environment

 

Note

 

The convector heater is made of various

 

metals and synthetic materials. The

 

heater also contains electronic parts,

 

which must be treated as electronic

 

waste. Please contact your dealer for

 

further information.

 

 

Only applicable to the European Union

 

Waste disposal of electric &

 

electronic equipment for business use. 

 

For further information regarding the

 

disposal of products for business use at

 

the end of their life span, please contact

 

your dealer or distributor in your country.

 

This product may not be disposed of

 

together with commercial waste or as

 

commercial waste.

1  

SAFETY INSTRUCTIONS

1.1  

Pictograms in this manual

 

Caution

 

Indicates risk of damage to the 

 appliance.

 

Warning

 

Indicates a dangerous situation, that

 

can lead to death or serious injuries.

 

Warning

 

Always switch off power when

 

performing maintenance or repairs on

 

the convector heater!

 

Hot

 

Some surfaces may be hot! Wait until

 

these parts have sufficiently cooled

 

down before performing maintenance.

 

Suggestions and tips to simplify the

 

carrying out of the specified tasks or

 actions.

1.2  

Lifting instructions (Fig. 2)

 

A Lifting hooks

 

B Shafts for lifting using a fork-lift truck

 

Warning

 

Do not use any unsuitable material for

 

lifting the convector heater.

.......................................... 5

..................................................... 6

................................................... 7

................................................................. 8

................................................... 9

............................................................ 10

................................................... 12

 

.................................... 12

 

.................................... 12 

Summary of Contents for IMAC 4000 GAS US

Page 1: ...IMAC 4000 GAS US USER MANUAL...

Page 2: ...2 40 020 950 rev 01 2019 IMAC 4000 US A B C D E F G H I J K L M N O P Q R 1 2 3 4...

Page 3: ...3 40 020 950 rev 01 2019 IMAC 4000 US 5 7...

Page 4: ...4 40 020 950 rev 01 2019 IMAC 4000 US Language English 5...

Page 5: ...bility For warranty and liability see general warranty regulations Environment Note The convector heater is made of various metals and synthetic materials The heater also contains electronic parts whi...

Page 6: ...ible mixture that is ignited by the spark between the electrodes The light of the flame that is created will activate the photocell This photocell checks whether a good combustion is brought about In...

Page 7: ...s Dizziness disorientation Difficulty breathing feels of being suffocated Proper ventilation air exchange OSHA 29 CFR 1926 57 to support combustion and maintain acceptable air quality shall be provide...

Page 8: ...Caution Only use natural gas of the family I2H and propane of the family 13P 4 Make sure there is sufficient distance between the wall and the air inlet Minimum distance is 1 m 5 Ensure that the heate...

Page 9: ...efore carrying out any maintenance 5 3 V belts Fig 7 Impression V belt tension 13 mm 32 2 N 1 Remove the upper and lower side panels A 2 Lower the motor B by turning the adjusting nuts C 3 Remove the...

Page 10: ...7 The air pressure switch has not closed Check the air hoses for dirt Replace if necessary Dealer 8 The maximum thermostat is stopping the convector heater Check and correct the air flow Reset the con...

Page 11: ...orcer plate are incorrect or dirty Correct the settings of the distributor holder and the forcer plate Clean the nozzle and the forcer plate Dealer 23 Exhaust opening or flue connection is in poor con...

Page 12: ...e switched off 31 The magnet valve or valves will not close Close the cock see fig 8 B User Contact your dealer Dealer The convector heater stops 32 An overheating problem has occurred in the convecto...

Page 13: ...ion Check the temperature resistance of the hose used Contact your dealer for information about the maximum length of the exhaust hoses bends manifolds and hose clamps The maximum static pressure in t...

Page 14: ...14 40 021 119 rev 00 2019 IMAC 4000 GAS US English Date Description Maintenance or Failure Action by A...

Page 15: ...15 40 021 119 rev 00 2019 English IMAC 4000 GAS US Date Description Maintenance or Failure Action by...

Page 16: ...pressure propane PSI iwc 0 27 5 8 0 27 5 8 0 32 8 8 Inlet Burner pressure natural gas PSI iwc 0 04 1 2 0 04 1 2 0 08 2 1 Air capacity m hr 18 000 24 000 24 000 CFM 10 595 14 715 14 715 Max pressure P...

Page 17: ...17 40 021 119 rev 00 2019 English IMAC 4000 GAS US...

Page 18: ...18 40 020 950 rev 01 2019 IMAC 4000 US...

Page 19: ...care but Thermobile Industries B V cannot be held liable for possible errors in the information or the consequences thereof The information provided herein may not be reproduced and or published in an...