background image

IMPORTANT

 Read this instruction manual. Failure to follow the instructions in this manual can result in 

damage to the unit, injury to operating personnel, and poor equipment performance.

CAUTION

 All internal adjustments and maintenance must be performed by qualified service personnel.

Material in this manual is for informational purposes only. The contents and the product it describes are 
subject to change without notice. Thermo Fisher Scientific makes no representations or warranties with 
respect to this manual. In no event shall Thermo be held liable for any damages, direct or incidental, arising 
from or related to the use of this manual.

© 2020 Thermo Fisher Scientific Inc. All rights reserved.

Summary of Contents for Smart Remote Contact

Page 1: ...User Guide 331676H03 Revision A 05 19 2020 Smart Remote Contact...

Page 2: ...med by qualified service personnel Material in this manual is for informational purposes only The contents and the product it describes are subject to change without notice Thermo Fisher Scientific ma...

Page 3: ...art Remote Contact 7 Architecture Overview 7 Requirements and Recommendations 8 Where to Find More Information 8 Using the Smart Remote Contact 9 Placement for Best Wireless Performance 9 Mounting Kit...

Page 4: ...Smart Remote Contact Set Up procedure in Web app 18 Alert Configuration for Smart Remote Contact in Web app 18 WEEE Compliance 20 Contact Information 24...

Page 5: ...EMOVE THE PRODUCT CASING NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION This product contains one non rechargeable 3 6V battery THE BATTERY IS NOT REPLACEABLE...

Page 6: ...o users CAUTION Do not use this device in explosive or hazardous environments unless the model is specifically approved for such use The device may cause sparks Sparks in explosive areas could cause e...

Page 7: ...pertains to 915 MHz wireless This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference 2 Thi...

Page 8: ...al and electronic equipment RoHS Directive 2011 65 EU and the amendment of EU 2015 863 Do not dispose of this product with household trash Thermo Scientific recycles this product under certain conditi...

Page 9: ...reading Smart Vue Pro sends the signal wirelessly via LoRa to the Smart Remote Contact device which opens or closes its relay to trigger alerts according to your needs The Smart Remote Contact provid...

Page 10: ...D and if test passes then it remains GREEN If the test fails it is indicated as RED Power supply 100 240 V AC 1 0 A auto switching power adapter International plugs included 1 5 meter about 5 ft cable...

Page 11: ...Pro web application for any or all your end point modules and groups For example you can configure a data logger to trigger an alarm if the temperature exceeds or drops below a specified limit The al...

Page 12: ...t device General Requirements and Recommendations For safety reasons the Smart Remote Contact device should be mounted less than 2 meters about 6 5 feet from the floor The AC adapter used for your wir...

Page 13: ...the floor and or shield the cord in a protective conduit that is fixed to the wall or within the wall The Smart Remote Contact is a critical device in your wireless monitoring system Therefore we reco...

Page 14: ...e used to trigger alerts using one or two external devices if alarm conditions are detected in your Smart Vue Pro wireless monitoring system Alarms and Alerts can be configured in the Smart Vue Pro we...

Page 15: ...ou may occasionally need to clean your Smart Remote Contact device depending on conditions at your site Here are some recommendations and guidelines for cleaning 1 Always unplug the device from its AC...

Page 16: ...ide for configuration details From where do we get the input commands to smart remote contact so that relay is triggered When Smart Vue Pro Webapp detects a new alarm then webapp sends the information...

Page 17: ...er during configuring the user setting i e Pin code set in web app by the user or by default it is 000000 Then in Advanced once a valid code is entered select the LoRaWAN select ON option from ON OFF...

Page 18: ...o save To save the settings save and restart to be selected Figure 9 WiFi Configuration Page c Press Test LoRaWAN Server in Smart Vue Pro LoRaWAN page after infrastructure is added in webapp This only...

Page 19: ...Infrastructure add the LoRaWAN details Figure 13 Create Infrastructure 10 To add a gateway in serial number field add the node id mentioned on the Gateway label Figure 14 Enter node id 11 To add a Sma...

Page 20: ...testing the Lora coverage on SVP Quatro start the data logging from either Equipment page or Data logger page by click the play icon 15 From Equipment page click start data logging Figure 18 Logging f...

Page 21: ...Alerts can be configured as required so that user would receive Emails SMS Voice calls based on the configuration whenever Smart Remote Contact is in Alarm condition 1 Navigate to Menu Configuration...

Page 22: ...n intend not to receive any alerts by configuring Days off Users that are selected from the Available users list under particular Day off tab while creating Alert rule would only receive the alert dur...

Page 23: ...m unter Services Support Conformit WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2012 19 EU in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici WEEE marcato col se...

Page 24: ...1 801 40 0 Belgium 32 53 73 42 41 32 2 482 30 30 France 33 2 2803 2180 33 2 2803 2180 Germany 0800 1 536 376 49 6184 90 6000 0800 1 536 376 Italy 32 02 95059 552 39 02 95059 552 432 254 375 Netherland...