background image

Thermo Scientific

MANUAL NUMBER 057-286-00 (7004301)

       7                  40139                     4/15/15          Updated warranty Information                                                                                         ccs

       6                  31361                     7/18/14          Removed CE reference on pg 2-4                                                                                    ccs

       5                  30954                     4/10/14          Updated Setting TImer for Continuous Shaking Step 3 - pg 5-8                                    ccs

       4                  30461                    10/21/13         Corrected suspension arms part number in Replacement Parts section                        ccs

       3                  29034                     9/10/12          Updated Hyperterminal information                                                                                ccs

       2                  27615                     7/22/11          Revised warranty                                                                                                              ccs

       1                  27135                     3/16/11          Added warranty pages                                                                                                     ccs

       0                      --                         4/20/10          Transfer to Marietta (was 057-286-00 5/15/09)                                                             ccs

    REV             ECR/ECN                   DATE           DESCRIPTION                                                                                                                By 

Preface

MaxQ 7000        i

Models covered in this manual

Model number

Voltage

SHKA7000 (4301)

208V

SHKA7000-1CE (4302)

220-240V

SHKE7000 (4303)

120V

SHKE7000-1CE (4304)

240V

Summary of Contents for SHKA7000

Page 1: ...Visit us online to register your warranty www thermoscientific com labwarranty User Manual MaxQ 7000 Benchtop Water Bath Shakers Operating Manual and Parts List 057 286 00 7004301 Rev 7...

Page 2: ...rrected suspension arms part number in Replacement Parts section ccs 3 29034 9 10 12 Updated Hyperterminal information ccs 2 27615 7 22 11 Revised warranty ccs 1 27135 3 16 11 Added warranty pages ccs...

Page 3: ...ormance s Caution All internal adjustments and maintenance must be performed by qualified service personnel s Material in this manual is for information purposes only The contents and the product it d...

Page 4: ...quipment that has been put on the market after 13 August 2005 This product is required to comply with the European Union s Waste Electrical Electronic Equipment WEEE Directive 2002 96 EC It is marked...

Page 5: ...l your needs for spare or replacement parts or provide you with on site service We can also provide you with a quotation on our Extended Warranty for your Thermo Scientific products Whatever Thermo Sc...

Page 6: ...4 5 Operation 5 1 Analog Units 5 1 Time r 5 1 Speed Control and Display 5 1 Power Switch 5 1 Temp Controller Setting Temperature 5 2 Temperature Calibration 5 3 Turning Shaker On 5 4 Digital Units 5...

Page 7: ...le 7 1 Secondary Overtemp Thermostat 7 3 Care and Cleaning of Stainless Steel 7 4 The pH Factor 7 4 Cleaning Methods 7 5 Cleansing Agents 7 5 Refilling the Tank 7 6 Cleaning the Low Water Level Sensor...

Page 8: ...utlet of correct voltage and current handling capacity 2 Disconnect from the power supply prior to maintenance and servicing To avoid personal injury 1 Do not use in the presence of flammable or combu...

Page 9: ...e equipment or are specified for it Substituting other attachments or accessories can produce hazards or make the unit inoperative 9 Perform regular maintenance service as specified in this manual and...

Page 10: ...1 kg Bath Chamber Dimensions Length 16 41 cm 16 41 cm 16 41 cm 16 41 cm Width 14 36 cm 14 36 cm 14 36 cm 14 36 cm Height 7 5 19 cm 7 5 19 cm 7 5 19 cm 7 5 19 cm Electrical Standard Temperature Voltag...

Page 11: ...inch 1 27 cm 3 individual LED displays indicate temperature time and speed simultaneously 3 characters height inch 1 27 cm Mutable Alarms None None Audible portion of the alarm can be silenced for a p...

Page 12: ...tion from 1 to 60 minutes Continuous operation hold or timed operation from 1 to 60 minutes Beeps twice when time has expired Shaking motion stops Beeps twice when time has expired Shaking motion stop...

Page 13: ...e deviates more than 2 C over set point unit will automatically shut down Audible and visual signals indicate when water level is too low Temperature range SHKA7000 SHKA7000 1CE SHKE7000 SHKE7000 1CE...

Page 14: ...mity available on request MaxQ 7000 2 5 Thermo Scientific Section 2 Specifications Environmental Operating Conditions Pollution Degree 2 Installation Category II Altitude 2000 meters MSL Mean Sea Leve...

Page 15: ...ature High Limit Light Illuminates when high limit thermostat is controlling chamber temperature 4 Speed Control Sets platform rotation speed 5 Power Switch Turns power on and off to shaker 6 Speed Ta...

Page 16: ...ates when speed is being set 7 Stop Switch Stops platform rotation 8 Start Switch Starts platform rotation 9 Power Switch Turns power on and off to shaker 10 Up Arrow Key Increases shaking time 11 Dow...

Page 17: ...20 Up Arrow Key Increases temperature 21 Down Arrow Key Decreases temperature 22 High Limit Light Indicates high limit control has been activated 23 Water Light Indicates water level in tank is below...

Page 18: ...ipt of shipment absolves the carrier from any liability for damage Call for a damage inspection promptly Use the packing list below when unpacking to verify that the complete unit has been received Do...

Page 19: ...the power source when not in use Warning Do not operate shaker with a damaged electrical cord s 1 Place shaking platform on suspension arms The short leg of each arm goes under the platform the longer...

Page 20: ...chlorinated tap water or additives that contain chlorine will void the manufacturer s warranty Similarly high purity deionized water that does not fall within a resistivity range of 50K to 1M ohm will...

Page 21: ...oil on the back of tank Cooling coil is shaped to fit around the heater Two compression fittings accommodate 5 16 0 79cm OD inlet and outlet tubing supplied by user 6 Re install suspension arms and pl...

Page 22: ...els are securely clamped before turning on unit Wherever possible vessels should contain a stopper to prevent hazardous substances being thrown out during the mixing action 1 Position the test tube ra...

Page 23: ...kwise to increase speed and counterclockwise to decrease speed The markings on the outside of the dial are for reference purposes only 2 The speed control tachometer provides an analog readout of the...

Page 24: ...r heaters are receiving power The lamp will normally flash when the chamber temperature is at set point 3 SET POINT ADJUSTMENTS The temperature controller normally displays the chamber temperature To...

Page 25: ...les shown at the left and the thermometer value obtained in step above enter the correct Zero value into the controller by pressing the STAR key and using the up or down arrow key If there is already...

Page 26: ...point 7 When desired temperature is achieved load the shaker Warning Do not operate shaker if any of the temperature controls become inoperative A hazardous condition will develop which can result in...

Page 27: ...er s up or down arrow keys 2 Measure current shaker speed by using a digital hand held tachometer 3 If the tachometer reading matches the shaker display no calibration is necessary If the tachometer r...

Page 28: ...urn power switch ON 3 Rotate high limit control fully clockwise 4 Set bath temperature 5 Allow sufficient time for bath temperature to stabilize before setting the high limit control 6 Rotate high lim...

Page 29: ...set point temperature to read 37 C or any other desired set point 5 Allow sufficient time for chamber temperature to stabilize 6 Press HEAT ON button and while continuing to hold press and release th...

Page 30: ...R ELAPSED switch until ELAPSED light is illuminated The HOURS or MINUTES light will also light up at this point depending on which option was previously chosen 2 Press HOURS MINUTES switch for desired...

Page 31: ...at COM1 is selected under Connect Using Click OK 5 In the COM1 Properties box Port Settings folder select the following options Bits per second 19200 Data bits 8 Parity None Stop bits 1 Flow control N...

Page 32: ...panel Press any switch on control panel Digital check if elapsed timer is flashing Reset timer Analog check if timer is in off position Set timer for continuous or timed operation Analog check if pow...

Page 33: ...of mild soapy water Use a soft cloth sponge or synthetic sponge scrubber Rinse all components thoroughly and dry completely DO NOT USE chlorine bleach chlorine based cleanser abrasives ammonia steel w...

Page 34: ...possible deposits within the bath 6 Remove adapter fitting when complete Note The drain is located on the front of the cabinet and is opened when the 0 64 cm adapter fitting is inserted Draining the...

Page 35: ...r panel 3 Locate the thermostat access opening located in the insulation retainer just above the shaker mounting plate These holes are not visible and must located by feel Each thermostat has a small...

Page 36: ...directly on the surface of stainless steel trapping moisture that becomes oxygen starved but is surrounded by water containing oxygen s Check pH regularly If pH is 6 0 add disodium phosphate to incre...

Page 37: ...aning of coffee marks humidifiers or vaporizers A 15 to 35 phosphoric acid solution is available from laboratory supply distributors for scale and rust removal Allow solution to soak the surface affec...

Page 38: ...o determine what would be best for your stainless steel product and laboratory To keep the low water level sensor operating properly it must be inspected weekly and cleaned every 2 weeks Remove any sc...

Page 39: ...00 1CE Timer 270 135 00 SHKA7000 SHKE7000 15 Amp Circuit Breaker 330 124 00 SHKA7000 1CE SHKE7000 1CE 10 Amp Circuit Breaker 330 119 00 SHKA7000 SHKA7000 1CE 0 7 Amp Circuit Breaker 330 250 00 Heater...

Page 40: ...er cannot process your request then contact Technical Services Prior to returning any materials contact our Technical Services Department for a Return Materials Authorization number RMA Material retur...

Page 41: ...ght bulbs and lid gaskets are excluded from this warranty Extended warranties are dependent on the units being maintained regularly as stated in the operation and service manuals Replacement or repair...

Page 42: ...e glass filters light bulbs and lid gaskets are excluded from this warranty Extended warranties are dependent on the units being maintained regularly as stated in the operation and service manuals Re...

Page 43: ...d direction prior to performance of any repairs Expendable items i e glass filters light bulbs and lid gaskets are excluded from this warranty Extended warranties are dependent on the units being main...

Page 44: ...and direction prior to performance of any repairs Expendable items i e glass filters light bulbs and lid gaskets are excluded from this warranty Extended warranties are dependent on the units being m...

Page 45: ...mo Fisher Scientific and its subsidiaries Specifications terms and pricing are subject to change Not all products are available in all countries Please consult your local sales representative for deta...