background image

20

One Year Limited Warranty

This Thermo Scientific product is warranted to be free of defects in materials and workmanship for one (1)

year from the first to occur of (i) the date the product is sold by the manufacturer or (ii) the date the product is

purchased by the original retail customer (the “Commencement Date”). Except as expressly stated above, the

MANUFACTURER MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, WITH RESPECT TO THE

PRODUCTS AND EXPRESSLY DISCLAIMS ANY AND ALL WARRANTIES, INCLUDING BUT NOT LIMITED

TO, WARRANTIES OF DESIGN, MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

An authorized representative of the manufacturer must perform all warranty inspections. In the event of a

defect covered by the warranty, we shall, as our sole obligation and exclusive remedy, provide free replace-

ment parts to remedy the defective product. In addition, for products sold within the continental United States

or Canada, the manufacturer shall provide free labor to repair the products with the replacement parts, but

only for a period of ninety (90) days from the Commencement Date.

The warranty provided hereunder shall be null and void and without further force or effect if there is any (i)

repair made to the product by a party other than the manufacturer or its duly authorized service representa-

tive, (ii) misuse (including use inconsistent with written operating instructions for the product), mishandling,

contamination, overheating, modification or alteration of the product by any customer or third party or (iii) use

of replacement parts that are obtained from a party who is not an authorized dealer of Thermo Scientific prod-

ucts.

Heating elements, because of their susceptibility to overheating and contamination, must be returned to the

factory and if, upon inspection, it is concluded that failure is due to factors other than excessive high tempera-

ture or contamination, the manufacturer will provide warranty replacement. As a condition to the return of any

product, or any constituent part thereof, to the factory, it shall be sent prepaid and a prior written authorization

from the manufacturer assigning a Return Materials Number to the product or part shall be obtained.

IN NO EVENT SHALL THE MANUFACTURER BE LIABLE TO ANY PARTY FOR ANY DIRECT, INDIRECT,

SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, OR FOR ANY DAMAGES RESULTING FROM

LOSS OF USE OR PROFITS, ANTICIPATED OR OTHERWISE, ARISING OUT OF OR IN CONNECTION

WITH THE SALE, USE OR PERFORMANCE OF ANY PRODUCTS, WHETHER SUCH CLAIM IS BASED ON

CONTRACT, TORT (INCLUDING NEGLIGENCE), ANY THEORY OF STRICT LIABILITY OR REGULATORY

ACTION.

For the name of the authorized Thermo Scientific product dealer nearest you or any additional information, contact us:

2555 Kerper Blvd., Dubuque, Iowa, 52004-0797

Phone: 563-556-2241 or 1-800-553-0039

Fax: 563-589-0516

Web: www.thermo.com

Summary of Contents for Precision WB159910-33

Page 1: ...Precision Water Bath Catalog No WB159915 WB161015S WB160025 WB160535 WB160635 WB160745 WB160855 WB159910 33 WB161010S 33 WB160020 33 WB160530 33 WB160630 33 WB160740 33 WB160850 33 LTM1599X1 7 8 08...

Page 2: ...n 8 Repositioning the Control Panel 9 Filling the Unit 10 Controls and Indicators 10 Operation 12 Power Up 12 Setting the Temperature Units to F or C 13 Setting the Temperature Setpoint 13 Setting the...

Page 3: ...cessor controlled for precise temperatures and reliable trouble free operation Dual thermostats one controlling the set point temperature and the other operating as a safety virtually eliminate the po...

Page 4: ...on the front panel for easy access To assure set point security the tempera ture can only be changed by entering a specific set menu first This ensures that the set point cannot be accidental ly alter...

Page 5: ...ounded power plug Use only properly grounded outlets to avoid a shock hazard This unit is not rated for use in hazardous atmospheres Do not continue to operate the bath if the tempera ture control fai...

Page 6: ...with proper ventilation Use the cover to reduce evaporation and to permit reaching higher temperatures Hot liquids pose a burn hazard Be careful not to reach into the bath when it contains hot liquid...

Page 7: ...ee 2 IEC 664 CE Products meet the relevant EC harmonized stan dards for safety IEC1010 1 EN61010 and EMC EN55014 EN55104 EN61000 4 2 4 4 4 6 4 11 and ENV50140 Applies to 230V units only 7 Specificatio...

Page 8: ...s Provide an adequate source of power Check the label on the back of the unit for voltage and current requirements Provide adequate clearance to insert samples Be level fixed and capable of supporting...

Page 9: ...positioned on the side or the front of the unit in order to achieve the best use of available bench space To change the position of the control panel follow these steps 1 Turn off the unit and discon...

Page 10: ...period 5 If using water algicide may be added to reduce algae formation Follow the instructions supplied with the algicide Controls and Indicators All controls and indicators are located on the front...

Page 11: ...e if you do not touch any control for a few seconds Set When in the normal mode of operation allows you to change the temperature setpoint When in the _C_F mode allows you to change the temperature un...

Page 12: ...ring this time the dis play will show the unit s capacity in liters 2 When the unit has completed its self test it will maintain the bath at the last setpoint tempera ture The Heat indicator will ligh...

Page 13: ...ee the current set point The Program indicator illuminates to show that this is the setpoint If this setpoint is correct there is no need to change the setting The display will return to normal operat...

Page 14: ...1 setting the Safety higher Calibrating the Unit To check the accuracy of the unit clip a certified ther mometer not supplied with water bath to the side of the bath as described in the installation i...

Page 15: ...ur the liquid from the unit into an appropriate disposal container 3 If you have any other size water bath allow the unit to cool and use the hand pump to empty the unit into an appropriate disposal c...

Page 16: ...r call Technical Support Very slow heating of samples Empty tank or extremely low liquid level in tank add liquid to the tank to improve heating Unit heating up slower than Defective controller call T...

Page 17: ...Hinge rim for 2S 5 10 20 liter SPN102459 Clip thermometer for 2L shallow SPN102423 Clip thermometer all except 2LS SPN102424 Microbicide 8 oz Bottle 13 641 337 Pump Siphon SPN102391 Controller PC boa...

Page 18: ...18 Schematics...

Page 19: ...19...

Page 20: ...misuse including use inconsistent with written operating instructions for the product mishandling contamination overheating modification or alteration of the product by any customer or third party or...

Reviews: