Summary of Contents for Invitrogen PowerEase Touch PS0120

Page 1: ...se Only Not for use in diagnostic procedures PowerEase Touch 120W Power Supply Catalog Numbers PS0120 115 VAC PS0121 230 VAC PS0122 230 VAC Australia PS0123 230 VAC China Publication Number MAN0019502...

Page 2: ...n history Pub No MAN0019502 Revision Date Description A 0 28 August 2020 New document Important Licensing Information These products may be covered by one or more Limited Use Label Licenses By use of...

Page 3: ...nstant Power 13 Custom methods 13 Select a pre programmed method 14 Manage methods 16 Save a method 16 Edit a method 17 Delete a method 18 Change the name of a saved method 18 Add a step 19 Delete a s...

Page 4: ...trument safety 31 Avoid electrical shock 31 Avoid damage to the instrument 31 Explanation of symbols and warnings 32 Symbols and warnings 32 Product regulatory compliance 33 Federal Communications Com...

Page 5: ...e Sturdy polyurethane feet and stackable housing design allow stacking of power supplies Running modes include Constant Voltage Constant Power or Constant Current Programming capabilities for limiting...

Page 6: ...er Rear view of PowerEase Touch 120W Power Supply The USB port is shipped with a plastic dust cover for protection during shipment This cover must be removed prior to port use Remove by gently prying...

Page 7: ...Zealand customers should use the Type I power cord Table 1 Cat No PS0120 115 VAC Component Quantity Regulatory mark s on electrical plug PowerEase Touch 120W Power Supply 1 each Extra Fuse 1 each Typ...

Page 8: ...ence Card 1 each Certificate of Performance 1 each Table 4 Cat No PS0123 230 VAC China Component Quantity Regulatory mark s on electrical plug PowerEase Touch 120W Power Supply 1 each Extra Fuse 1 eac...

Page 9: ...ectrophoresis product we recommend that you adhere to the protocols given in the electrophoresis product manuals For best results We recommend using the Constant Voltage Mode for protein gels or blots...

Page 10: ...to the power supply by inserting the positive lead into the red output jack and the negative lead into the black output jack 7 Turn the AC power switch at the back of the power supply On Programming o...

Page 11: ...will appear on the Home screen when the power supply is switched on for the first time or it if is switched on after running an unsaved custom method see below The Last run option will appear on the H...

Page 12: ...creen to bring up the Run parameter edit screen Default maximum values are 300 V 500 mA and 120 W Note When using constant voltage or constant power it is recommended that the maximum default settings...

Page 13: ...may cause the voltage to increase to the maximum capacity of the power supply This may lead to local overheating and damage to the electrophoresis cell or create unsafe conditions Note When operating...

Page 14: ...horesing midi gels sold by Thermo Fisher Scientific Inc Selecting Western blots brings up a list of preloaded methods for transferring above gels to Western blots 3 To view method options not availabl...

Page 15: ...r your gel may be slightly different than the default value given by the pre programmed method The default run times shown in mini gel pre programmed methods assume the use of the Mini Gel Tank Thermo...

Page 16: ...ited pre programmed method by touching Edit 3 Touch the Name of method field in the Save As screen to bring up a keyboard that will allow entry of the method name Method names can contain a maximum of...

Page 17: ...od touch the data field for the parameter you wish to change Selecting a run parameter will bring up its Edit screen 2 Enter the parameter value required then press Enter Note Do not save custom metho...

Page 18: ...ist of displayed methods then press Delete If several methods have been saved swipe up as you would with a smart phone to scroll down the list Figure 10 Managing saved methods Change the name of a sav...

Page 19: ...previous step or right arrow next step 3 When all of the steps have been entered touch Start run to initiate the run To previous step To next step Figure 11 Method step number location Delete a step 1...

Page 20: ...ings screen Run screen features Method name The name of the method will be displayed at the top of the screen If the method is an un named custom method the name displayed will be the method type Cons...

Page 21: ...rt back to the set method constant parameter 200 V in this case and the crossover icon will no longer be displayed Figure 12 shows a run with crossover to mA and current limited to 40 mA For additiona...

Page 22: ...be displayed Screen for non saved custom methods Screen for saved or pre programmed methods Figure 13 Run complete screens Settings The PowerEase Touch 120W Power Supply is equipped with a number of...

Page 23: ...tness Allows adjustment of screen brightness Press to increase brightness or to reduce brightness Volume Allows adjustment of beeper volume Press to increase volume or to reduce volume Sleep mode Allo...

Page 24: ...FAT32 format and have a maximum capacity of 32 GB 2 On the Settings screen touch Software update see Figure 14 The power supply will search for update files on the USB drive This will take several sec...

Page 25: ...uffer levels then press Restart to restart the run Operation stops with alarm Display shows Over Voltage Output voltage was too high and the power supply stops the output Verify cable connections Veri...

Page 26: ...un Excessive buffer evaporation Ensure electrophoresis settings and buffer concentration is correct Ensure wire connections are intact Press Resume to continue the run or Restart to restart the run Lo...

Page 27: ...l fuses contact support see Appendix F Documentation and support 1 Turn off the power switch and detach the power cord at the rear of the power supply unit 2 Open the fuse compartment located inside t...

Page 28: ...p the cover closed and re attach the power cord Figure 16 Rearview of PowerEase Touch 120W Power Supply Appendix B Repair and maintenance Replace the fuse B 28 PowerEase Touch 120W Power Supply User G...

Page 29: ...ing highly conductive chloride ions in the gel are gradually replaced by the slower moving less conductive glycine ions from the running buffer as the gel runs As a result the resistance of the gel in...

Page 30: ...in watts or the rate of heat generated by the system is directly proportional to voltage and current P IV Appendix C Electrical parameters for electrophoresis Power C 30 PowerEase Touch 120W Power Su...

Page 31: ...d on the screen WAIT at least 5 seconds after stopping a run before handling output leads or connected apparatus ALWAYS make sure that hands work area and instruments are clean and dry before making a...

Page 32: ...ION Pour minimiser les consequences n gatives sur l environnement la suite de l limination de d chets lectroniques ne pas liminer ce d chet lectronique avec les d chets usuels non soumis au tri s lect...

Page 33: ...perated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful inter...

Page 34: ...voltage Operating Modes Constant Voltage Constant Current Constant Power 1 V step 1 mA step 1 watt step Timer Up to 999 min per step Crossover Automatic Display type Backlit TFT LCD Graphic type Displ...

Page 35: ...x D x H Operating temperature 0 C 40 C Environmental conditions 95 RH non condensing 75 KPa 106 KPa altitude not to exceed 2 000 meters Weight 2 1 kg Certifications CE cTUVus RCM China RoHs Warranty 1...

Page 36: ...protocols Certificates of Analysis Safety Data Sheets SDSs also known as MSDSs Note For SDSs for reagents and chemicals from other manufacturers contact the manufacturer Limited product warranty Life...

Page 37: ......

Page 38: ...rEase Touch 120W Power Supply v1 GUID 2A50B62D 5D3E 4FAD AC0E 5932C78C18E1 2020 08 11 05 14 52 en 22 50 05 958 01 00 thermofisher com support thermofisher com askaquestion thermofisher com 28 August 2...