Communication Option
Communications Test
Thermo Scientific
7-3
Screen for each controller found connected to PC. The factory-set addresses
are 1, 2, 3, ets., depending on the number of controller's address to be
changed. See
Section “Address for multiplier controller”
for detailed
instructions on configuring multiple controllers.
9. After the instrument scan is completed, a SpecView window appears with the
message, "All channels scanned. Press OK to continue, or cancel to rescan".
Press OK if all of the connected controllers are properly displayed. If no
controls are displayed, check the "troubleshooting" section at the end of this
setup.
10. To begin communication between the PC and the controller, click on the “Enter
Runtime” button (an icon of a running figurine). This action will ask for a file
name to save this display: use the given default or select another.
11. The "Spec View" window will be displayed, showing the current PV (process
variable) and SP (set point). If the SpecView display of the controller shows
X's, the communication connection or power to the control may have been
interrupted.
12. On some controllers, the decimal point position has been changed from the
YOKOGAWA factory default. This will make the SecView display differ from
the controller. If this is the case, follow the instructions in
Communications Test
When you have established a working communications link between the controller
and PC, you should check the link by varying the target set point function:
1. Click on the arrows of the controller(s) shown in the SpecView window. This
will open a keypad window where the set point can be changed.
2. Select a temperature set point a few degrees from the current temperature and
press the “send” button. Verify that the controller display shows the setpoint
change.
3. Select the original temperature set point through the keypad on the controller
and observe the change on the PC display.
4. The controller parameters may be viewed through SpecView by clicking on the
“PAR” button. A window opens that lists the controller parameters. Each
parameter can be changed by selecting it and clicking on the “Alter" button.
Select the “Close” button. Make no changes at this time.
This concludes the initial software diagnostics.
Summary of Contents for CC58114PBC
Page 1: ......
Page 6: ...List of Figures ii Thermo Scientific ...
Page 12: ...Introduction 2 2 Thermo Scientific ...
Page 14: ...Unpacking 3 2 Thermo Scientific ...
Page 20: ...Installation Thermocouple Wiring Installation 4 6 Thermo Scientific ...
Page 22: ...Initial Start up 5 2 Heratherm Thermo Scientific ...
Page 46: ...Communication Option Addresses for Multiple Controllers 7 6 Thermo Scientific ...
Page 50: ...Excess Temperature Option Excess Temperature Controller Operation 8 4 Thermo Scientific ...
Page 57: ...Replacement Parts Thermo Scientific Heratherm 11 3 Figure 5 Wiring Diagram ...
Page 58: ...Replacement Parts 11 4 Heratherm Thermo Scientific ...
Page 59: ...Thermo Scientific 12 1 12 Error Codes This chapter is not applicable ...
Page 60: ...Error Codes 12 2 Thermo Scientific ...
Page 62: ...WEEE Compliance 13 2 Thermo Scientific ...
Page 63: ...Thermo Scientific 14 1 14 14 Spare Parts and Accessories This chapter is not applicable ...
Page 64: ...Spare Parts and Accessories 14 2 Thermo Scientific ...