background image

Please

 

read

 

the

 

manual

 

carefully

 

and

 

follow

 

the

 

following

 

safety

 

guidelines

 

before

 

operating

 

this

 

instrument.

1. Keep this manual for reference.
2. Professionals

 

are

 

required

 

to

 

operate

 

 

   the

 

instrument.

3. The instrument can only be used with 
     the original power adapter.
4. When

 

operating

 

the

 

instrument, the

 

 

   operator must choose to

 

wear 

    appropriate

 

clothing

 

to

 

avoid

 

toxic

 

 

   and

 

harmful

 

solvents

 

produced

 

as

   

    follows:

    

Harmful

 

liquids

 

splashed

    

The

 

harmful

 

solids

 

ejected

    

Body, hair, clothing

 

is

 

rolled

 

or

 

corroded         

5. If the instrument becomes abnormal 

 

   or higher vibration in use, please immediately

 

   reduce the speed accordingly, If the

 

   instrument becomes abnormal or 

    there is a higher vibration when in use, 
    immediately reduce the speed accordingly 
    or immediately stop the instrument 
    but turning off the power.
6. Ensure that the accessories and 
    containers are installed correctly.
7. Check that the instrument and the 
     accessories are in good condition 
     before each operation.

8. For a single test tube mixing, please 
     put test tube in the middle hole of the 
     rubber platform. For multi-test tube 
     mixing, please always place the test 
     tubes in the center and symmetrically.
9. Be

 

careful

 

of

 

the

 

risks

 

that

 

may

 

arise.

    

Flammable

 

substances

    

Fragile

 

substances

10. Unplug

 

the

 

power

 

before

 

installing

 

       the

 

accessories.

11. Carefully handle the instrument to 
       avoid any collision or impact.

Section 6  Safety Tips and Maintenance

Cleaning

In

 

order

 

to

 

ensure

 

the

 

safe

 

use

 

of

 

the

 

instrument, please

 

follow

 

the

 

manufacturer’s

 

recommendations

 

when

 

cleaning

 

the

 

instrument.

● 

Unplug

 

the

 

power

 

first

 

when

 

cleaning.

● 

Wipe

 

the

 

instrument

 

with

 

a

 

damp, soft

  

    cloth or

 

non-corrosive

 

cleaning

 

agent 

● 

Direct spray

 

instruments are 

    prohibited.

● 

Make

 

sure

 

that

 

the

 

instrument

 

is

    completely

 

dry

 

before

 

operating

 

it.

 

Please

 

wear

 

gloves

 

when

 

cleaning.

Warning: Avoid dripping detergent or 
water into the inside of the instrument 
during cleaning.

Clean Spill
I

f accidental spillage of liquids caused by 

mishandling or contained breakage occurs 
on the surface of the instrument, please 
shut down the instrument and clean up 
the liquid immediately. If the liquid has 
already spilled into the unit, cut off the 
power supply first and immediately clean 
up the liquid at the surface of the instrument. 
Place the instrument in a ventilated and 
dry environment for 24 hours before reuse. 
If the instrument is not functioning after 
drying for 24 hours, please contact the 
manufacturer.

Warning:

 The operator is not permitted 

to gain access using a tool, to a part 
which in normal use may be hazardous 
live.

11      Section 6  |  Safety Tips and maintence

Basic Vortex Mixer       12

Summary of Contents for 88882011

Page 1: ...her com Find out more at thermofisher com In Canada For customer service call 1 800 234 7437 To fax an order use 1 800 463 2996 To order online thermofisher ca Operating Manual Revision A 04 01 2021 2021 Thermo Fisher Scientific Inc All rights reserved All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified ...

Page 2: ...ure Diagram Section 4 Overview Specifications Environmental Conditions Safety Instructions Section 5 Operation Control Panel Installation of Accessories Settings Section 6 Safety Tips and Maintenance Section 7 Troubleshooting Section 8 Optional Accessories Section 9 Warranty Section 10 Compliance Contents 1 2 3 3 4 4 4 4 5 5 5 6 7 7 8 10 11 13 14 15 16 ...

Page 3: ...roduct inefficiency Also this will void warranty Which also indicates a hazardous situation if not avoided may result in minor or moderate injury Do not put heavy things on the power cord Do not put the machine on the cord It may take off the wire coating and cause electric shock or fire Do not touch it with wet hands and place the main plug correctly It could cause the electric shock or injuries ...

Page 4: ...maximize the needs of customers It uses brushless DC motor with accurate speed control stability safe and reliable features DC motor design is suitable for long time operation up to 1 week or longer It has a power recovery function The housing material is ABS which has excellent heat resistance corrosion resistance impact resistance and chemical resistance 3 Section 2 Introduction 3 2 Connections ...

Page 5: ...3 Safety Instructions Please read the entire instruction manual before operating the Basic Digital Vortex WARNING DO NOT use the Basic Vortex Mixer in a hazardous atmosphere or with hazardous materials for which the unit was not designed Also the user should be aware that the protection provided by the equipment may be impaired if accessories used are no provided orrecommendedbythemanufacturer or ...

Page 6: ...bump of the Rubber Platform is to the groove on the base tray 2 Press evenly along the perimeter of the Rubber Platform so that the Rubber Platform is stuck on the base tray Installation of Flat Bottom Vessel Platform 1 Place the Flat Bottom Vessel Platform on the top of the base tray and align the inner bump of the Flat Bottom Vessel Platform is to the groove on the base tray 2 Press evenly along...

Page 7: ...r for the running mode is on Mode Settings In standby press button to switch Touch mode or Continuous mode In Touch mode the instrument starts running automatically when the vessel presses on the Rubber Platform or Flat Bottom vessel Platform and automatically stops when the vessel leaves the platform In Continuous mode press button the instrument with tray platform or tube holder starts running c...

Page 8: ...lammable substances Fragile substances 10 Unplug the power before installing the accessories 11 Carefully handle the instrument to avoid any collision or impact Section 6 Safety Tips and Maintenance Cleaning In order to ensure the safe use of the instrument please follow the manufacturer s recommendations when cleaning the instrument Unplug the power first when cleaning Wipe the instrument with a ...

Page 9: ...ple in the test tube Remove the objects contacted Section 8 Optional Accessories Description Cat No Figure Touch Continuous Speed Range Dimensions Rubber Platform 88882121 88882122 88882120 88882123 88882124 88882125 88882127 88882126 Microplate Tray Flat Bottom Vessel Platform 10mm dia x19 Tube Holder 15mm dia x 12 Tube Holder 20mm dia x 7 Tube Holder 26mm dia x 4Tube Holder 12mm dia x 13 Tube Ho...

Page 10: ...e and special application Outside the USA please contact local Thermo Technical Services Department or local distributor for warranty information Section 10 Compliance 1 European Union The European voltage models of this product meet all the applicable requirements of the European Directives and therefore display the CE Marking These Directives are captured in the EU Declaration of Conformity whic...

Page 11: ...lies with the requirements of the legislative act Administration on the Control of Pollution Caused by Electronic Information Products ACPEIP A label of conformance such as one of the following may be found on the product 5 End of Life Care Some considerations and suggestions are listed below for proper disposal of this product While addressing these actions for safe recycling and disposal please ...

Reviews: