Specifications

1.  Output based on Annual Fuel Utilization Efficiency rated by manufacturer.

2.  Seasonal Efficiency (also called AFUE - Annual Fuel Utilization Efficiency) ratings are based on tests following the U.S. Department of Energy  

  test procedures. 

3.  To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is required.

Form No. PL81410041003 - 

1/07 - 10Ms

Printed in the U.S.A.

© 2007 Thermo Poducts, LLC - North Judson, IN

Phone: 574-896-2133

www.thermopride.com

Model Number

OH6FX072DV4R

Heating Capacity

Low Capacity

High Capacity

Low Fire

High Fire

Low Fire

High Fire

Heat Input Rate (BTUH)

70,000

85,000

85,000

106,250

Output BTUH

1

61,500

74,000

74,000

91,000

Seasonal Efficiency

2

 (AFUE)

87.3

86.4

Largest Recommended A/C

3

4 Tons

4 Tons

Nominal Temperature Rise

64°

64°

64°

64°

Dimensions (inches) H x W x D

45” x 20” x 30”

Nominal Flue Outlet Diameter

5”

Approximate Shipping Weight (lbs.)

250

Quantity and Size of Permanent Filters

(1) 24-3/4” x 15-3/4”

Electrical Requirements

120 / 60 / 1

Maximum Fuse Size /ECM

15

Total Current (AMPS) /ECM

12.3

Height from Floor to Center of Flue

40-3/4”

Supply Air Outlet Size W x D

18” x 19”

Return Air Ductwork Connection

Flange Size on Filter D x H

24-1/2” x 15”

Return Air Inlet Opening Size in Side 

Casing (to be cut-out by dealer) D x H

23” x 14”

Accessory Items

Programmable Thermostat

350866

R

2-Stage Burner Easy Setup

The 2-Stage burner is easy to set up and service. Your 

contractor merely moves a pin and adjusts it for 

low fire as with a traditional burner, then moves the 

pin again and sets it up for high fire. Lastly, he will 

move the pin to the third setting to run. The burner 

will then switch from low to high fire automatically 

as needed. The burner is also mounted on a double 

hinge making it easy to service as needed.