SS-GM9S80-U

www.goodmanmfg.com

10/21

Heating Input : 40,000 – 80,000 BTU/h

Single-Stage, Multi-Speed ECM, 

Multi-Position, Ultra-Low NOx  

Gas Furnace

80% AFUE

Standard Features

Cabinet Features

•  Heavy-duty stainless-steel dual- 

diameter tubular heat exchanger

•  Single-stage gas valve
•  Durable Hot-surface igniter 
• 

Quiet, modulating draft inducer

• 

Self-diagnostic control board

• 

Multi-speed ECM blower motor

• 

Eligible for installation in California’s South Coast 

 

Air Quality Management District (SCAQMD) and San 

 

Joaquin Valley Air Pollution Control District (SJVUAPCD). 

This furnace complies with the 14 ng/J NOx emission 

limit in SCAQMD Rule 1111 and SJVUAPCD Rule 4905.

• 

AHRI Certified; ETL Listed

• 

Installation: upflow, 

 

horizontal left or right

• 

Convenient left or right connection 

 

for gas and electrical service

• 

Heavy-gauge steel cabinet with 

 

durable baked-enamel finish 

•  Foil faced insulated heat exchanger

Contents

Nomenclature ........................................

2

Product Specifications ...........................

3

Dimensions

 ............................................ 4

Airflow Data ........................................... 5

Wiring Diagrams

 ....................................

8

Accessories

 ............................................ 9

Minimum Filter Sizes 

 ............................ 9

GM9S80-U

*  Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty 

(good for as long as you own your home), 2-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must 

be completed within 60 days of installation. Online registration is not required in California or Quebec.

Summary of Contents for GM9S80-U Series

Page 1: ...n SCAQMD Rule 1111 and SJVUAPCD Rule 4905 AHRI Certified ETL Listed Installation upflow horizontal left or right Convenient left or right connection for gas and electrical service Heavy gauge steel ca...

Page 2: ...guration NOx M Upflow Horizontal N 40 NG J NOx C Downflow Horizontal X 40 NG J NOx U 14NG J NOx Motor Cabinet Width 9 Nine Speed ECM A 14 C 21 B 17 D 24 Gas Valve Maximum CFM C Two Stage 3 1200 CFM 4...

Page 3: ...System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Stand...

Page 4: ...s Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Standard of Canada CAN CSA B149 1 and CAN CSA B142 2 in Canada Note AMES80 approved for line contact in the horizontal position Model A B...

Page 5: ...8 1147 1107 1064 1027 990 F03 1295 1256 1214 1181 1140 1100 1062 1024 F04 1385 1337 1301 1260 1222 1186 1149 1114 F05 1454 1407 1372 1353 1325 1291 1255 1219 F06 1528 1485 1438 1409 1383 1349 1317 128...

Page 6: ...17 44 981 45 950 47 921 48 886 856 828 F06 1108 40 1068 42 1033 43 1003 44 972 46 942 914 882 F07 1274 35 1233 36 1203 37 1174 38 1146 39 1118 1089 1065 GM9S80 0604AU W W1 F02 1274 35 1228 36 1188 37...

Page 7: ...HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Tem...

Page 8: ...RMER 115 VAC 24 VAC BK SENSOR YL FLAME BR 1 GAS VALVE 2 M C BL BLOWER COMPARTMENT AUTO RESET AUXILIARY LIMIT CONTROL PU BL AUTO RESET PRIMARY LIMIT CONTROL PU BK GND BLOWER DRAFT ID INDUCED 1 2 3 RD W...

Page 9: ...x 25 Side or 1 20 x 25 Bottom Note Larger filters may be used filters may also be centrally located Use 2 16 x 25 filters on side returns or 20 x 25 filter on bottom return if furnace is connected to...

Page 10: ...man Manufacturing Company L P reserves the right to discontinue or change at any time specifications or designs without notice or without incurring obligations 2021 Goodman Manufacturing Company L P H...