background image

SS-

GME8

www.goodmanmfg.com

10/11

Supersedes 8/11

M

ulti

-P

osition

, D

ual

$

aver

  

M

ulti

-s

PeeD

 G

as

 F

urnace

Standard Features

•  Dual-diameter tubular heat exchanger 
•  Two-stage gas valve that allows installer to 

turn on two-stage operation with the flip  
of a dipswitch 

•  Energy-efficient circulator motor (EEM)
•  115V Silicon Nitride igniter designed for long 

igniter life

•  Furnace control board with self-diagnostics, color-coded 

low-voltage terminals, and provisions for electronic air 
cleaner and 24-volt humidifiers

•  Control board stores the last five diagnostic codes in 

memory; simple push-button activation outputs the fault 
history to a flashing red LED

•  Low constant fan allows homeowner to activate the low 

heat speed to efficiently circulate air throughout the home.

•  Self-adjusting feature automatically adjusts furnace to 

high- or low-stage operation based on outside tempera

-

ture without an outdoor temperature sensor

•  Certain models available with low NOx emissions

Cabinet Features

•  Fully insulated, heavy-gauge steel cabinet with durable 

baked-enamel finish

•  Foil-faced insulation lines the heat exchanger
•  Designed for multi-position installation: upflow,  

horizontal left or right

•  Removable bottom for side- or bottom-return applications
•  Convenient left or right connection for gas/ 

electric service

•  Top gas connection on most models
•  Coil and furnace fit flush for most installations

80% aFue

H

eatinG

 i

nPut

60,000–100,000 Btu/

H

GMe8

Contents

Nomenclature  ...................................................................2
Product Specifications  ......................................................

3

Dimensions  .......................................................................4
Airflow Data  ......................................................................

5

Wiring Diagram  .................................................................

7

Accessories  ........................................................................

8

 *  Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive 

the  Lifetime  Heat  Exchanger  Limited  Warranty  (good  for  as  long  as  you  own  your  home),  10-Year 
Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be 

completed within 60 days of installation. Online registration is not required in California or Québec.

Summary of Contents for GME80603B Series

Page 1: ...tempera ture without an outdoor temperature sensor Certain models available with low NOx emissions Cabinet Features Fully insulated heavy gauge steel cabinet with durable baked enamel finish Foil face...

Page 2: ...tal NOx D Dedicated Down ow N Natural Gas H High Air ow X Low NOx K Dedicated Up ow M Up ow Horizontal Cabinet Width A 14 Descrip2on B 17 V Two Stage Variable speed C 21 H Two Stage Mul speed D 24 S S...

Page 3: ...upon Isolated Combustion System ICS Vent diameter may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National...

Page 4: ...ibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater Refer to the appropriate USA and Canadian codes In the USA the National Fuel Gas Co...

Page 5: ...1 352 1 306 T3 4 1 750 42 1 750 42 1 707 43 1 667 44 1 610 46 1 574 1 531 1 486 T4 4 1 870 40 1 805 41 1 782 42 1 737 43 1 701 44 1 656 1 606 1 571 T5 5 2 297 2 297 2 224 2 106 35 2 014 37 1 896 1 813...

Page 6: ...60 70 80 90 110 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2...

Page 7: ...ect to change Always refer to the wiring diagram or the unit for the most up to date wiring W arning High Voltage Disconnect all power before servicing or installing this unit Multiple power sources m...

Page 8: ...er This furnace is capable of the following heating modes Single Stage Factory Setting Modified Two Stage Fixed 5 Min Low Stage Auto Time 1 12 Min Low Stage Start Call for Heat Safety Circuit Check St...