background image

P

roDuct

 s

PeciFications

P

roDuct

 s

PeciFications

2 www.goodmanmfg.com 

SS-GME8

n

oMenclature

   

Brand

Revisions

G Goodman

®

   Brand

A Ini.al   Release

or   Dis.nc.ons™

B 1st   Revision
C 2nd   Revision

Airflow   Direc2on

C

Downflow/Horizontal

NOx

D Dedicated   Downflow

N Natural   Gas

H High   Airflow

X Low   NOx

K

Dedicated   Upflow

M Upflow/Horizontal

Cabinet   Width

A 14”

Descrip2on

B 17½”

V Two-­‐Stage/Variable-­‐speed

C 21”

H Two-­‐Stage/Mul.-­‐speed

D 24½”

S

Single-­‐Stage/Mul.-­‐speed

Maximum   CFM   @   0.5”   ESP

AFUE

3 1,200

95 95%

4 1,600

9

90%+

5 2,000

8

80%

MBTU/h

040:   40,000

100:   100,000

060:   60,000

120:   120,000

080:   80,000

11

*

B

10

*

M

2

9

1

G

E
3

3

5,6,7

4

8

060

8

Summary of Contents for GME80603B Series

Page 1: ...tempera ture without an outdoor temperature sensor Certain models available with low NOx emissions Cabinet Features Fully insulated heavy gauge steel cabinet with durable baked enamel finish Foil face...

Page 2: ...tal NOx D Dedicated Down ow N Natural Gas H High Air ow X Low NOx K Dedicated Up ow M Up ow Horizontal Cabinet Width A 14 Descrip2on B 17 V Two Stage Variable speed C 21 H Two Stage Mul speed D 24 S S...

Page 3: ...upon Isolated Combustion System ICS Vent diameter may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National...

Page 4: ...ibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater Refer to the appropriate USA and Canadian codes In the USA the National Fuel Gas Co...

Page 5: ...1 352 1 306 T3 4 1 750 42 1 750 42 1 707 43 1 667 44 1 610 46 1 574 1 531 1 486 T4 4 1 870 40 1 805 41 1 782 42 1 737 43 1 701 44 1 656 1 606 1 571 T5 5 2 297 2 297 2 224 2 106 35 2 014 37 1 896 1 813...

Page 6: ...60 70 80 90 110 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2...

Page 7: ...ect to change Always refer to the wiring diagram or the unit for the most up to date wiring W arning High Voltage Disconnect all power before servicing or installing this unit Multiple power sources m...

Page 8: ...er This furnace is capable of the following heating modes Single Stage Factory Setting Modified Two Stage Fixed 5 Min Low Stage Auto Time 1 12 Min Low Stage Start Call for Heat Safety Circuit Check St...