Unit Operation
46
To restart the unit in Diesel Mode, proceed as follows:
•
Press the Standard Truck HMI Control Panel ON Key. The
Hourmeters display and a blinking Alarm Icon will appear.
•
When the Hourmeters display and a blinking Alarm Icon
is shown, press the Standard Truck HMI Control Panel ON
Key again. The display will go blank but the blinking
Alarm Icon will remain on and blinking.
•
When the display goes blank and the blinking Alarm Icon
is shown, press the Standard Truck HMI Control Panel ON
Key again. The box temperature and setpoint will appear,
the blinking Alarm Icon will disappear and the unit will
start in Diesel Mode.
Selecting CYCLE-SENTRY or
Continuous Mode
When CYCLE-SENTRY mode is selected the unit will start
and stop automatically to maintain setpoint, keep the engine
warm and the battery charged. When Continuous Mode is
selected, the unit starts automatically and runs continuously to
maintain setpoint and to provide constant airflow throughout
the truck box.
CYCLE-SENTRY Mode or Continuous Mode is selected by
pressing the CYCLE-SENTRY/CONTINUOUS Key when the
unit is turned on. If the unit is running in Continuous Mode,
pressing this key will switch operation to CYCLE-SENTRY
Mode and the amber LED indicator will glow. If the unit is
running in CYCLE-SENTRY Mode, pressing this key will
switch operation to Continuous Mode and the amber LED will
turn off.
The unit shown in Figure 32 is running in CYCLE-SENTRY
Mode.
Figure 32: CYCLE-SENTRY/Continuous Key
CAUTION: The engine may start automatically any time the
unit is turned on.