12
ENGLISH
List of user parameters
Menu
Par.
No.
Description
Range
Default set-
ting
UM
Main menu
0000
013
Quick adjustment of direct Zone/Zone 1 heating setpoint in 0 and
3 heating modes.
By connecting the zone control accessory, this parameter can be
used to quickly change direct Zone/Zone 1 setpoint. This param-
eter simultaneously modifies the value of Par. 2103.
See Par. 2103
See Par. 2103 °C
0000
023
Quick adjustment of Zone 2 heating setpoint in 0 and 3 heating
modes.
By connecting the zone control accessory, this parameter can be
used to quickly change Zone 2 setpoint. This parameter simulta-
neously modifies the value of Par. 2203.
See Par. 2203
See Par. 2203 °C
0000
033
Quick adjustment of Zone 3 heating setpoint in 0 and 3 heating
modes.
By connecting the zone control accessory, this parameter can be
used to quickly change Zone 3 setpoint. This parameter simulta-
neously modifies the value of Par. 2303.
See Par. 2303
See Par. 2303 °C
0000
047
Quick adjustment of DHW setpoint with heater
See Par. 2047
°C
0000
048
Quick adjustment of DHW setpoint with instant production
See Par. 2048
°C
0000
201
Stops the venting function
0 = No action
1 = Stop venting
0…1
0
0000
901
Unit of measurement for temperature
0 = °C
1 = °F
0...1
0
0000
902
Pressure unit of measurement
0 = BAR
1 = PSI
0...1
0
Info menu
1000
1101
Direct Zone/Zone 1 delivery temperature
°C
1000
1102
Direct Zone/Zone 1 ambient temperature
°C
1000
1201
Zone 2 delivery temperature
°C
1000
1202
Zone 2 ambient temperature
°C
1000
1301
Zone 3 delivery temperature
°C
1000
1302
Zone 3 ambient temperature
°C
1000
1001
CH flow temperature
°C
1000
1002
Domestic hot water temperature
°C
1000
1003
Domestic cold water temperature
°C
1000
1004
Outdoor temperature
°C
1000
1007
Return temperature
°C
1000
1033
System pressure
bar