35
LUNA 2T | MAINTENANCE
6.3
Faults, causes and solutions
F
aUlT
C
aUse
s
olUTion
U/i/a
The heat pump
does not start
Lack of voltage
Check for voltage
I
Check upstream safety systems
U
Main switch in pos. OFF
Set to ON
U
Remote switch in OFF position
Set to ON
U
Control panel in OFF position
Set to ON
U
Main switch in OFF position
Set to ON
U
Compressor thermal-magnetic
circuit breaker to OFF
Set to ON
I
Low supply voltage
Check the power supply line
I/A
Faulty compressor
Replace the component
I/A
Insufficient
performance
Lack of refrigerant
Check charge
I
Incorrect sizing of the equipment
Check
I
Operation outside the operating
conditions recommended by the
manufacturer
Check parameters
I
Compressor
loud
Part of the cooling circuit in
contact with the structure
Check
I
Return of liquid to the compressor Check
A
Unsuitable unit fixing
Check
I
Power cable with inverted phase
Reverse a phase
I
Noise and
vibrations
Contacts with metal bodies
Check
I
Loose or missing screws
Tighten the screws
I
High compression
delivery pressure
(over 35 bar)
Fan stopped in summer mode
Check
I
High system water temperature in
winter mode
Check
I
High DHW circuit temperature
Check
I
Air in the hydraulic system in
winter operation
Vent the air from the circuit
I
Thermostatic expansion valve
failure in heating mode
Check and if necessary replace
the component
A
Insufficient flow to the DHW heat
exchanger in DHW operation
Check the pump
I
Insufficient flow to the system heat
exchanger in winter operation
Check the pump
I