INSTALLATION OF THE FAN
NOTE: TheTHR 100 must be installed horisontally and therefore NEVER mounted on a ceiling.
The following steps must be followed when installing THR 100.
ENGLISH
»
INS
TALL
ATION OF THE F
AN
Measure out on the wall for where the fan is to
be placed.
NOTE: TheTHR 100 must be mounted AT LEAST
2.3 metres above floor level.
Remove the four cover caps from the screw ho-
les in the exhaust hood.
Drill a hole of 110 mm in the wall.
NOTE: There should be a downward angle of
between 2 and 5 degrees from the inside and
out.
Measure out and pre-drill the four holes for the
exhaust hood.
Install rawl plugs suitable for the material into
which they are installed.
Mount the exhaust hood on the wall.
1
3
4
2
5
6
Mount the cover caps onto the screws in the
exhaust hood.
Push the pipe and the heat recovery core into
the hole in the wall.
NOTE: Make sure that the cut section of pipe
faces down to avoid the wire from the fan be-
coming trapped.
Remove the front panel from the fan.
7
8
9
110 mm
110 mm
2-5 %
x4
x4
x4