THERMEX (ANTARES) HM 24 - HM 28 room sealed 
conventional boilers are wall hung boilers designed 
to meet your needs for heating your house as well 
as preparing domestic hot water by using natural 
gas. The boilers are suitable for natural gas fuel.
This installation and usage manual contains detailed 
instructions and recommendations for safe and efficient 
use of the boiler, further this manual contains technical 
data, information for installation and connections, use, 
maintenance, troubleshooting and explanation of the 
most possible failures of the appliance.
Please do not operate your appliance before 
reading this manual and to keep in a safe place for 
future reference.

a.

  Installation and connections of the boiler must be 

carried out in full conformity with the governing 
legal regulations, the requirements of local 
gas distributing Company and the instructions 
provided by the manufacturer.

b. 

Ensure that the flue gas connection is not terminated 
in a closed compartment and connected with no 
other appliance but the special chimney made 
to be used for the connection of more than one 
appliance and flue gas outlet cap is not clogged.

c. 

Ensure that the supply gas complies with the 
gas type, pressure and capacity of the boiler 
indicated in the data plate.

d. 

Ensure that both central heating system and 
domestic hot water distribution pipes are cleaned 
properly before the installation and connection to 
the boiler. The manufacturer is not responsible 
of any damages arising from the dirt and small 
particles left inside the piping and such failures 
and damages are out of warranty claim.

e. 

The commissioning of the boiler must be performed 
by qualified personnel/Thermex authorised 
services only. Ensure that electric, water and gas 
connections to the boiler are carried out are in 
conformity with local requirements as well as to 
the instructions provided in this manual.

f. 

Cleaning of external surfaces of the appliance 
should be made by using a damp cloth, do not 
use any chemical or detergent.

g. 

The appliance is not designed for children use 
so its installation is made in such way to make 
children difficult to access.

h.

 In order to use the appliance efficiently for years 

to come schedule annual maintenance of the 
boiler with Thermex authorised service.

The THERMEX warranty claim does not apply any 
failures arising from any use of the appliance out of 
such mentioned in this manual as well as from the 
following cases:

a.

 Happened in appliances not commissioned by 

authorised THERMEX services,

b. 

Arising from installations not confirming the 
instructions given in this manual as well as those 
from misuse,

c. 

Arising from selecting a wrong location for the 
appliance,

d. 

Arising from selecting wrong type of appliance 
for the intended purpose,

e. 

Arising from intervening the appliance by an 
unauthorized service agency,

f. 

Physical failures happened after the appliance 
has been delivered,

g. 

Arising from natural disasters, fire and lightning 
strike,

h. 

Arising from high or low supply voltage out of 
the limits stated in the data plate or connections 
to a power supply line with an inefficient earth 
connection,

i. 

Arising from the failure of observing the periodic 
maintenances specified in the instructions to be 
done in time by the authorized service agencies,

j. 

Arising from other accessories and ancillary 
products used with the appliance,

k. 

Arising from freezing if antifreeze protection 
cannot be activated due to a cut of power and 
gas supply,

l.

  Manipulation of data plate and warranty certificate,

m. 

Using the appliance in a cold water supply network 
out of the conditions set in this instruction manual,

The warranty does not apply to above specified 
failures, and repair of such failures is subject to a fee.

INTRODUCTION

WARNINGS FOR THE USER

1

2

CONDITIONS INELIGIBLE
FOR WARRANTY

3

Summary of Contents for Antares HM 24

Page 1: ...Thermex Antares HM 24 HM 28 Room Sealed Conventional Combi Boiler www thermex com tr Conventional Combi Boiler Installation And User s Manual Read carefully before operating the appliance ...

Page 2: ...LIGIBLE FOR WARRANTY 3 4 SWITCHING ON THE BOILER 4 5 DAILY OPERATION OF THE BOILER 4 6 FILLING THE BOILER 4 7 SWITCHING OFF THE BOILER 5 8 MAINTENANCE OF THE BOILER 5 9 INSTALLATION INSTRUCTIONS 5 10 DIMENSIONS OF THE BOILER 6 11 FLUE CONNECTION 6 12 ELECTRIC CONNECTION 7 13 ELECTRIC SCHEME AND ROOM THERMOSTAT 8 14 ERROR CODES 8 15 TECHNICAL DATA 9 INDEX ...

Page 3: ...r are carried out are in conformity with local requirements as well as to the instructions provided in this manual f Cleaning of external surfaces of the appliance should be made by using a damp cloth do not use any chemical or detergent g The appliance is not designed for children use so its installation is made in such way to make children difficult to access h In order to use the appliance effi...

Page 4: ...sign may be pressed to make desired selection To set hot water temperature you may use buttons to set the desired temperature In Summer mode pump anti blocking safety and anti frost protection are active b When the appliance is in Winter mode the display shows and signs To set this mode the button with Mode sign may be pressed to make desired selection c To set Central Heating temperature you may ...

Page 5: ...ns to the boiler and ensure that the installation pipes are free from dirt or any particles Boiler package contains Boiler support Styrofoam installation hanging equipment user s manual warranty certificate and service booklet The locations where the boiler can be installed should beselected by observing the relevant regulations and requirements set forth by standards codes of practice in force as ...

Page 6: ...ended off the wall it must extend minimum 50 mm outside the wall d Horizontally connected flue connections must be installed with 1 downward slope e Where the appliance is installed to penthouses flue terminal should be minimum 40 cm above the roof In such cases the roof must be insulated with non combustible material f Maximum length of the flue connection is 4 m Maximum length is shortened by 1 met...

Page 7: ... connection through 3 10 A Automatic circuit breaker 7 Thermex Antares Room Sealed Conventional Combi Boiler Installation and User s Manual ENG ELECTRIC CONNECTION 12 Figure 10 L max 5 m Figure 8 Figure 9 L1 L2 3 m Total equivalent 5 m L1 L2 L3 3 m Total equivalent 5 m 90 elbow equal to 1 m flue length 45 elbow equal to 0 5 m flue length L1 L1 L2 L3 L 2 L1 L1 L2 L3 L 2 Product Total Equivalent Flu...

Page 8: ...es and warnings to the user through the LCD display Figure 13 In such case if the error does not disappear after performing the indicated action the closest authorised service must be called to fix the error of the appliance ELECTRIC SCHEME AND ROOM THERMOSTAT ERROR CODES 13 14 DESCRIPTION OF THE ERROR ERROR CODE REQUIRED ACTION No fire warning E01 RESET the boiler Flue gas sensor warning E02 RESET...

Page 9: ...1 39 Expansion Vessel Capacity Liter 8 8 Expansion Vessel Pre charged Pressure bar 1 1 Domestic Hot Water DHW System DHW Heating Power Max kW 23 1 27 2 DHW Heating Power Min kW 9 3 11 4 DHW Volume T 30 C Max l min 11 13 DHW Volume T 25 C Max l min 13 2 15 6 DHW Temperature Adjustment C 30 60 30 60 Maximum Operating Pressure bar 9 9 Minimum Operating Pressure bar 0 3 0 3 Electrical Specifications P...

Page 10: ...0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 0 000 0 500 1 000 1 500 2 000 2 500 3 000 III II I 6 5 4 3 2 1 0 0 000 0 500 1 000 1 500 2 000 2 500 3 000 III II I 6 7 5 4 3 2 1 0 0 000 0 500 1 000 1 500 2 000 2 500 3 000 III II I 100 0 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 0 000 0 500 1 000 1 500 2 000 2 500 3 000 III II I 100 0 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 0 000 0 500 1 0...

Page 11: ...ion about the appliance THERMEX in order to develop improve its products preserves the right to modify instruction and user s manual without prior notice 11 Thermex Antares Room Sealed Conventional Combi Boiler Installation and User s Manual ENG ...

Page 12: ...www thermex com tr Dear Customer Thank you for choosing a Thermex product Revision 2 25 04 2020 ...

Reviews: