THERMASOL.COM
I
800.776.0711
Steam Suite Spa Package
Connect the data cable to steam generator connector.
(The other end of the cable runs to the back of the control in
the the shower location or to the SWM-2 or PDM if present.
DO NOT pinch, nail, staple, wedge, or
bind the data cable.
DO NOT wrap the data cable around
steam line or route it in a manner so
that the hot steam line could melt
the cable.
Any damage to the control cable
will result in the control not working
properly.
Carefully connect the data cable to
the generator and control BEFORE
turning power on to the generator.
"ON"
Turn Clockwise
"OFF" Turn
Counter Clockwise
• Do not staple, strain or damage data cable
• Align pins to receptacle visually before tightening
• Do not force plug
• Hand tighten only
Connector
Detail
Back of
control
or side of
generator
Side of generator
Contact pins
Contact pins Cable ends
Back of
control
or side of
generator
3
Control Installation and Data Cable Connection
BY THERMASOL
4
Sealing Control
Step 1: Coat the entire groove on the control back with supplied water-
proof silicone to fully seal the control to the wall. Completely seal the
control to the wall so moisture does not collect behind it.
Step 2: Place the control on the wall pressing firmly.
(You may need to tape the control into place until the silicone dries.)
Be careful not to harm the wall or control with the tape.
Let dry for 24 hours before using steam bath.
IMPORTANT: Fully test the control system prior to silicone.
1/2" hole for surface mount