Water Supply and Drain Pan

THERMASOL.COM  

I

  800.776.0711

Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. 

Once you select the generator location, 
you will need to run water to the unit.

DO NOT use galvanized fittings. Use copper or brass fittings only!

DO NOT use PEX or PVC tubing.

DO NOT plumb the pressure relief valve into the steam line.  
Plumbing the pressure relief valve into the steam line can be  
hazardous, should the steam outlet be capped off or obstructed. 

Recommend installing unions on all rigid pipe lines for ease of 
removal and serviceability (if required).

 

Use 3/8" NPT line.

 

Plumb the 3/4" drain connection on pan to an approved drain. 

 

Drain Pan must be installed on all generator installations.  

 

All plumbing shall be performed by a qualified 

 

licensed plumber and in accordance with 

 

applicable national and local codes. 

 

Connect a tee to the existing cold water line.

 

Install copper pipe from the tee to create inlet line for unit.

 

Install a brass shut off valve on the water inlet line 

 

in an accessible area in front of the brass union (and  

 

recommended in-line water filter). A stainless steel water 

 

supply flex connector may be used. 

 

Before making the water connection, flush the water line  

 

into a five-gallon pail to remove any silt or other materials that  

 

may be in the water inlet line.

  

 

Make final connection but DO NOT turn the water on yet.

A

D

B

E

C

A

D

B

E

C

Steam Suite Spa Package

Water Inlet Line

(3/8" NPT with brass

shut-off valve)

3/4" Drain Line

Steam Line

5

BY THERMASOL

Summary of Contents for SSDA-135

Page 1: ...Steam Suite Spa Package Installation Operation Manual thermasol com solutions BY THERMASOL ...

Page 2: ...E AGE OF 16 UNLESS SUPERVISED BY AN ADULT THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING PURPOSES THERMASOL STEAM BATH GENERATORS ARE FOR INDOOR USE ONLY THEY SHOULD NEVER BE LOCATED OUTSIDE THE HOME All products must be installed in accordance with installation instructions provided Failure to do so may invalidate warranty at manufacturer s discretion 2018 ThermaSol...

Page 3: ...AGE KW RATING AMPS PHASE WIRE BREAKER MAX ROOM SIZE SSDA 135 208 240VAC 8 37 1 8 40 175 CU FT SSDA 390 208 240V AC 11 55 1 6 60 395 CU FT The size of the shower will determine the size of the generator The size of the generator will determine electrical requirements o All the electrical wiring must be done per National Local Electrical Codes o Run 240V Power source to the generator o Use copper wi...

Page 4: ...and must be in a dry non combustible well ventilated space with 6 clearance around generator When constructing the ceiling add slope of 1 foot The control cable provided with the generator is 50 feet in length Item 03 6152 050 When locating the control unit place it as far as possible away from the steam head and as close as is practical to where the user will be sitting The generator must be upri...

Page 5: ...ain connection on pan to an approved drain Drain Pan must be installed on all generator installations All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes Connect a tee to the existing cold water line Install copper pipe from the tee to create inlet line for unit Install a brass shut off valve on the water inlet line in an acces...

Page 6: ... steam must be unobstructed DO NOT plumb any traps in the steam line The steam outlet on the generator requires a 1 2 brass union for easy installation not included Use 1 2 brass pipe or copper tubing from unit to steamhead rough in fitting as permitted by code A B The steam line can run up and then down once or horizontal but never run down and then up If it does a steam trap will be produced at ...

Page 7: ...ce a location is selected drill a 7 8 hole in the shower wall Connect a 1 2 NPT brass pipe or copper tubing to the steam outlet union not included on the generator running the pipe to the steam head location in the wall to connect with the steamhead It is very important that the pipe is firmly secured to the wall Install a 1 2 drop ear elbow on the end of the 1 2 pipe or tubing Connect 1 2 copper ...

Page 8: ...1 2 SELECT STEAM 1 Signature Series Control INSTALLATION INSTRUCTIONS 8 ...

Page 9: ...E STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS AS THIS CAN BE HAZARDOUS TO YOUR HEALTH YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJU...

Page 10: ...emporary style shown here Installation instructions warranty static cling warning label Silicone 2 Tools and Materials Parts enclosed BY THERMASOL Route the data cable included with generator through the finished wall to the back side of the control The other end of the cable runs to the steam generator location or if present to SWM 2 or PDM NOTE It is recommended to run the cable through electric...

Page 11: ...r damage data cable Align pins to receptacle visually before tightening Do not force plug Hand tighten only Connector Detail Back of control or side of generator Side of generator Contact pins Contact pins Cable ends Back of control or side of generator 3 Control Installation and Data Cable Connection BY THERMASOL 4 Sealing Control Step 1 Coat the entire groove on the control back with supplied wa...

Page 12: ...erature by touching the UP symbol until desired temperature is displayed Press Select Return button Reduce the temperature by touching the down symbol until desired temperature is displayed Press Select Return button Setting the timer Press the or button until you reach the time menu Press Select Return button Set the timer of your ThermaSol steam shower by using the or button symbols which are lo...

Page 13: ...Serenity Light and Music System INSTALLATION INSTRUCTIONS 13 ...

Page 14: ... USE THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS AS THIS CAN BE HAZARDOUS TO YOUR HEALTH YOUR SHOWER MAY BE A SLIP AND FALL HAZARD CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING...

Page 15: ...Backing Board o Amplified FM antenna with coax cable FROM STEAM UNIT TO SHOWER CONTROL FROM FM ANT FROM 12 VDC Tighten retaining spring to half its normal height Plywood Waterproof Backing Mortar Finished Show er Surface 3 1 2 x 1 4 threaded rod bolt studs Retaining nut Retaining washer Retaining spring Fig 1 Installation Profile View 50 foot CAN bus cable Item 03 6152 050 Steam Suite Spa Package ...

Page 16: ...e printed template to drill the three 7 16 holes Then proceed cutting the cutout Note Template must be printed out at actual size Install suitable wood support between joists 7 16 Cutout Signature Series Control sold separately 50 foot CAN bus cable Item 03 6152 050 ships with Serenity Light Template see page 22 50 foot CAN bus cable to Steam Generator not included Steam Suite Spa Package THERMASO...

Page 17: ...d inspection Mount in area where it is out of common contact High voltage wires from transformer must be connected to a 10amp minimum 110 VAC receptocal Installation must follow national and local building code WARNING Make sure there is no insulation or combustible material within 8 inches of the transformer No material should touch the transformer Connect the Audio cable that is connected to the...

Page 18: ...ith the finished ceiling material apply silicone around center groove on back of the fixture Push fixture tight against ceiling See sheet 3 for instructions on tightening the fixture to the ceiling Allow silicone to dry for 24 hours Silicone Bead all around the perimeter of groove Push fixture tight against the ceiling Securing Serenity Light 5 Signature Series Control sold separately 50 foot CAN ...

Page 19: ...Template must be full scale 1 1 when printed 1 2 3 4 5 5 7 6 1 2 3 4 5 6 7 Steam Suite Spa Package BY THERMASOL ...

Page 20: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM BY THERMASOL 81224_NC ...

Reviews: