Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details. 

THERMASOL.COM  

I

  800.776.0711

Steamhead Location

Steamhead rough-in fitting 
to be installed flush and 
sealed to finished wall

C

C

Insert protective cap
into housing

Insert installation tool and 
tighten housing into place
with a 1" socket and driver

6

DO NOT 

install the steamhead near the seating area or the user.

DO NOT 

forget to install the steamhead rough-in fitting! 

Installthesteamhead24"fromthefloororbathtubrim

and 6" from any corner.

Steamhead is to be mounted as far as possible from 
typical bathing position (seated or standing) and installed 
as far from the in-shower controller as possible.

For retrofit to existing finish wall: 

Drill a 1-1/8" diameter hole in the shower wall or wall above 

bathtub rim for the steam outlet rough-in fitting and install 
to be flush with the finished wall. this housing must be 

sealed to the wall to not allow vapor or water behind it. 
(plumbing must be done from backside of  

finshed space)

 

For new framing: 

Mount and install rough-in fitting to be 

flush with finished wall.

Connect a 1/2" NPT brass pipe or copper tubing to
the steam outlet union (not included) on the generator
running the pipe to the steam head location in the wall

to connect with the steamhead rough-in fitting. It is very

important that the pipe is firmly secured to the wall, so

that when the steamhead is installed it doesn’t push the

rough-in fitting back into the wall. Install a 1/2” dropear

elbow on the end of the 1/2” pipe or tubing for the

rough-in fitting. 

Use the installation tool to tighten the housing in place  
with a 1" socket and driver. Then insert the protective cap 
into the housing.

For all the connections, use solder for copper joints and 

Teflon tape for pipe fittings and do not over tighten fittings. 

DO NOT USE PVC CEMENT.

MicroTouch Control and Steamhead Installation Instructions

6

 

Steamhead Installation

Summary of Contents for MicroTouch Control

Page 1: ...MicroTouch Control OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Operation Manual thermasol com solutions ...

Page 2: ...OR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY IF YOU ARE FEELING UNCOMFORTABLE DIZZY FAINT OR STARTING TO FALL ASLEEP IMMEDIATELY EXIT THE STEAM ROOM DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLES...

Page 3: ...wall Materials needed o MicroTouch control o CAN bus cable o Silicone o Other materials as required Tools needed o Pipe wrench o Tubing cutter o Wire cutters or wire strippers o Adjustable wrench o Screwdriver Phillips and regular o Solder and flux o 1 1 16 masonry drill bit o 1 1 2 hole saw for surface mount rough in OR 3 hole saw for recessed mount o Drill motor o Other tools as required Control...

Page 4: ...e data cable DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable Any damage to the control cable will result in the control not working properly Carefully connect the data cable to the generator and control BEFORE turning power on to the generator ON Turn Clockwise OFF Turn Counter Clockwise Do not staple strain or damage data cable ...

Page 5: ... fully seal the control to the wall Completely seal the control to the wall so moisture does not collect behind it Place the control on the wall pressing firmly You may need to tape the control into place until the silicone dries Be careful not to harm the wall or control with the tape Let dry for 24 hours before using steam bath A Square Control shown Round Control shown A 3 hole for recessed mou...

Page 6: ...ng and install to be flush with the finished wall this housing must be sealed to the wall to not allow vapor or water behind it plumbing must be done from backside of finshed space For new framing Mount and install rough in fitting to be flush with finished wall Connect a 1 2 NPT brass pipe or copper tubing to the steam outlet union not included on the generator running the pipe to the steam head ...

Page 7: ...move the protective cap and insert the steamhead into housing Use the supplied silicone to adherethe steamhead to the wall sealing out any water from getting behind the head Use supplied o ring lubricant to assist in steam head installation A very small amount is all that is need directly on the o rings Upon final installation mount steamhead with facing up to allow aromatherapy well to dispense s...

Page 8: ...r Changing the Temperature Set Point Set the temperature of your ThermaSol steam shower by using the lit plus or minus symbols which are located immediately to the left and to the right of the power icon An arc array of lit squares will appear from left to right Increase the temperature by touching symbol until desired temperature is displayed by the blue LED lights running clockwise to indicate a...

Page 9: ...uch Control and Steamhead Installation Instructions Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details THERMASOL COM I 800 776 0711 9 ...

Page 10: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM 81181 C ...

Reviews: