5'
8'
Installation note
We do not recommend a
ceiling height exceeding
10 feet.
Lowering ceiling
height to 8 feet helps
create a more efficient
steam room.
3
THERMASOL.COM
I
800.776.0711
If you are installing the unit or thinking of adding one on your next project,
you will need to make sure the unit is sized properly.
Calculate the shower area
(Length x Width x Height = Cubic Feet)
and confirm the ceiling height does not exceed 8 feet.
The set of numbers in the generator model number
represents the maximum capacity.
Example:
Generator model SSA-240
will be sufficient up to 240 cubic feet
(with a ceiling not exceeding 8 feet in height).
Up-size 1 Unit size for every foot over 8 foot to
a maximum of 10 foot.
Model number can be found on the box or generator.
ThermaSol’s generators can be placed up to 50 feet from the
shower; in an attic, closet or below a sink are ideal locations.
Make sure the walls, ceiling and floor materials are suitable for
use with steam. If using acrylic walls, they must be steam rated
from their manufacturer. ThermaSol only recommends SSA-ACR
generator for acrylic modules.
q
Wire cutters or wire strippers
q
Adjustable wrench
q
Screwdriver (Phillips and regular)
q
Solder and flux
q
1-1/8" inch hole saw for ThermaSol
SteamVection steamhead rough-in
q
Drill motor
q
Propane torch
q
1" socket with ratchet
q
Other tools as required
Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.
The size of the shower will determine the size
of the generator. The size of the generator will
determine electrical requirements.
q
All the electrical wiring must be done per
National/Local Electrical Codes.
q
Run 240V Power source to the generator.
q
Use copper wire only.
q
Wire sizes recommended by NEC (2002 Version). Minimum wire
temperature rating 90°C. Type THHN.
q
Each generator should be wired to their own separate breaker
q
Turn off all electricity to the working area at the main breaker panel!
q
Leave power OFF during installation process.
AF Series Generator Installation Instructions
3
Sizing or Double Checking the Unit Specified
MODEL
INPUT VOLTAGE KW RATING AMPS PHASE WIRE BREAKER
ELECTRICAL
MAX. ROOM SIZE
SSA-ACR
208-240VAC
3.5
17
1
10
20
NEMA 6-30P
Acrylic Shower
SSA-84
208-240VAC
6.0
28
1
10
30
NEMA 6-30P
84 CU.FT.
SSA-140
208-240VAC
8.0
37
1
8
40
NEMA 6-50P
140 CU.FT.
SSA-240
208-240VAC
10
46
1
8
50
NEMA 6-50P
240 CU.FT.
SSA-395
208-240VAC
11
55
1
6
60
Hardwire
395 CU.FT.
SSA-575
208-240VAC
15
69
1
4
90
Hardwire
575 CU.FT.
ThermaSol requires that a licensed electrician perform all electrical work.