4.  Attach window-lock bracket to window sash with one of the #8 x 

3/4 slotted wood screws to secure window in place. 

5.  Plug into a grounded 3 prong outlet. 

6.  Press PESET on the power supply cord. 
 

 

 
 

 

 

__________________________________________________________________________________________________________________ 

AIR CONDITIONER USE

 
Operating your air-conditioner properly helps you obtain the 
best possible results.

 

 
This section explains proper air conditioner operation 
 

IMPORTANT

If you turn the air conditioner off, wait at least 3 minutes before 
turning it back on. This prevents the air conditioner from blowing 
a fuse or tripping a circuit breaker. 

 

Do not try to operate your air conditioner in the cooling mode when 
outside temperature is below 65º F (18ºC). The inside evaporator coil 
will freeze up, and the air conditioner will not operate properly. 
 

NOTE

: in the event of a power failure, your air conditioner will 

operate at the previous settings when power is restored. 

 

 

 

Starting Your Air Conditioner-Digital Control 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

NOTES:    

When the air conditioner is off, the display shows the

 

                current room temperature. 
 
 

If the room temperature is below 55ºF (13ºC), the display  

                will show 55ºF (13ºC). If the room temperature is above  
               99ºF (37ºC), the display will show 99ºF (37ºC). The display   
               operation ranges from 64 to 86 ºF. 
 
1.    Press POWER to turn on the air conditioner. 
 
 
 
 
 

 
 Note:

 When the air conditioner is turned on for the first time after it 

is plugged in, it will display the default settings: Cool mode, Turbo 
fan speed, 72ºF (22ºC) for 3 seconds. When it is turned on at all 
other times, it will default to the previous settings. 
 
2.  Select mode. See “Mode”. 
 
3.  Select fan speed. See “Fan Speed” 
 
4.  Set temperature. See “Temperature”. 
 
______________________________________________________ 
  

MODE

 

______________________________________________________ 
 
1. Press MODE until you see the indicator light come on for the 
setting you desire. 
 

2. 

Choose Cool, Fan Only or Power Saver. 

 
 
 
 
 

Cool

 – Cools room. You can adjust temperature by  

                 pressing the plus or minus button. You can select fan 
                 speed by pressing Fan Speed. 
 

 

 

Fan Only

 – Only the fan will run. You can select the fan 

 

speed by pressing Fan Speed, but you can not adjust the 

 

temperature control setting. The display shows the current 

 room 

temperature. 

 
               

 NOTE

: Auto fan speed cannot be selected in Fan Only 

mode. 

 

             

 Power Saver

 – The fan and compressor run when cooling 

is needed. When this feature is selected, the fan will turn 
off when the temperature is satisfied. The fan and 
compressor will operate only as required to satisfy the set 
temperature. 

 

Compressor restarts in 3 minutes after the unit stops. 
Compressor will not stop running for the first 6 minutes 
after restarting unless unit is turned off.  

       
              

 NOTE

: After 3 seconds, display will show the current room 

temperature. 

 
_______________________________________________________ 

FAN SPEED 

_______________________________________________________ 
1. Press FAN SPEED until you see the indicator light come on for the 
setting you desire. 
 
2. Choose Turbo, High, Low, or Auto 
 
 
 
 
3. In the Auto setting, the fan speed automatically adjusts depending 
on the room temperature. 
_______________________________________________________ 

FILTER RESET 

_____________________________________________________ 
1. 

When FILTER indicator light is lit or flashing, remove, clean and 
replaces the air filter. See “Changing the Air Filter”. 

2. 

Replace air filter. 

3. 

Press and hold FILTER after replacing the air filter. 

 
 
 

Summary of Contents for WAC6115R

Page 1: ...950 0075 revD Page 1 of 15 9 May 2007 WINDOW AIR CONDITIONER INSTALLATION AND OPERATION CATALOG NO PRODUCT CODE WAC6115R 420 0005 WAC8115R 420 0008...

Page 2: ...e safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and follow all safety instructions This is the safety alert symbol...

Page 3: ...installation Tools Needed The location should provide Flat Blade and Phillips screwdrivers Tape measure Level Drill and 3 32 or smaller bit Scissors Utility Knife Parts Supplied on some models Check t...

Page 4: ...screw located in lower right corner of air conditioner when air conditioner is in cabinet The electrical ratings for your air conditioner are listed on the model and serial number label The model and...

Page 5: ...shown 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET on some devices a green light will turn on 3 Press TEST Listen for a click Reset button will trip and on some devices a gree...

Page 6: ...lation or removal The location where the power cord exits the air conditioner Should be no more than 4 ft 122cm from a grounded 3 prong outlet Do not block the louvers on the front panel Do not block...

Page 7: ...own Complete Installation 1 Insert foam seal behind the top of the lower window 2 Pull left hand curtain out until it fits into the window channel sash and against the glass of the upper window Repeat...

Page 8: ...ious settings 2 Select mode See Mode 3 Select fan speed See Fan Speed 4 Set temperature See Temperature ______________________________________________________ MODE ____________________________________...

Page 9: ...e 1 to 24 hours 4 Press TIMER again or wait 10 seconds Timer indicator light will remain on Display will show current room temperature To set the timer to turn on the air conditioner changing the prev...

Page 10: ...0 seconds Indicator light on air conditioner control panel will remain on To set Timer to turn on air conditioner changing the previous settings 1 Turn on air conditioner 2 Adjust Mode to Cool Fan Onl...

Page 11: ...er cabinet _______________________________________________________ Annual Maintenance Your air conditioner needs annual maintenance to help ensure steady top performance throughout the year Call your...

Page 12: ...room Check the cooling capabilities of your room air conditioner Room air conditioners are not designed to cool multiple rooms The filter is dirty or obstructed by debris Clean the filter The inside e...

Page 13: ...CORD RATING amps 15 POWER CORD TYPE LCDI POWER CORD LENGTH 4 MIN CIRCUIT BREAKER SIZE A 15 MIN CIRCUIT CAPACITY A 6 9 REFRIGERANT CHARGE lbs oz R22 0 81 13 SOUND dba H M L 62 59 57 4 WAY AIR ADJUSTME...

Page 14: ...G amps 15 POWER CORD TYPE LCDI POWER CORD LENGTH 4 MIN CIRCUIT BREAKER SIZE A 15 MIN CIRCUIT CAPACITY A 9 5 REFRIGERANT CHARGE lbs oz R22 1 72 27 5 SOUND dba H M L 56 52 49 4 WAY AIR ADJUSTMENT NO 2 W...

Page 15: ...ger registration period This warranty provides free replacement of defective parts only Labor and replacement parts as a result of normal wear and tear are not covered under this warranty Additional c...

Reviews: