AIR CONDITIONER CARE 

 

Your new air conditioner is designed to give you many years of 
dependable service. This section tells you how to clean and care for 
your air conditioner properly. Call your local authorized dealer for an 
annual checkup. Remember… the cost of this service call is your 
responsibility. 
_______________________________________________________ 

Cleaning the Air Filter 

The air filter is removable for easy cleaning. A clean filter helps 
remove dust, lint, and other particles from the air and is important for 
best cooling and operating efficiency. Check the filter every 2 weeks 
to see whether it needs cleaning. 

NOTE:

 Do not operate the air conditioner without the filter in place. 

1.   Turn off air conditioner. 
 
2. Remove air filter by sliding filter out from either side of unit. 
 
3.   Use a vacuum cleaner to clean the air filter. If air filter is very 
dirty, wash it in warm water with a mild detergent. Do not wash air 
filter in the dishwasher or use any chemical cleaners. Air dry filter 
completely before replacing to ensure maximum efficiency. 
 
4. Replace air filter by sliding filter back into either side of unit. 
 
 
 
 
 
 
 

_______________________________________________________ 

Cleaning the Front Panel 

 
1. Turn off air conditioner 
 
2. Remove the air filter and clean it separately. See Cleaning the Air 
Filter. 
 
3. Wipe the front panel with a soft, damp cloth. 
 
4. Air dry front panel completely. 
_______________________________________________________ 
 

Repairing Paint Damage 

 
Check once or twice a year for paint damage. This is very important, 
especially in areas near oceans or where rust is a problem. If 
needed, touch up with a good grade enamel paint. 
 

NOTE:

 To reduce paint damage during the winter, install a heavy 

duty cover over air conditioner cabinet. 
_______________________________________________________ 

Annual Maintenance 

 

Your air conditioner needs annual maintenance to help ensure 
steady, top performance throughout the year. Call your local 
authorized dealer to schedule an annual checkup. The expense of 
an annual inspection is your responsibility. 

______________________________________________________________________________________________________________________ 

TROUBLESHOOTING 

 

Before calling for service, try the suggestions below to see whether you can solve your problem without outside help. 
 
_______________________________________________________ 
Air Conditioner will not operate 
_______________________________________________________ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The power supply cord is unplugged.     

Plug into a grounded 3 

prong outlet. See “Electrical Requirements”. 
 
 
 
 
 
 
 
 
 

The power supply cord has tripped (Reset button has popped 
out). 

Press and release RESET (listen for click; Reset button will 

latch and remain in) to resume operation. 
 

A household fuse has blown, or a circuit breaker has tripped. 

Replace the fuse or reset the circuit breaker. If the problem 
continues, call an electrician. See “Electrical Requirements”. 
 

Depending on model, the Power button has not been pressed or 
the Fan control is turned to Off. 

Press POWER or turn the Fan 

control to an active setting. 
 

The local power has failed. 

Wait for power to be restored. 

 
_______________________________________________________ 

Air Conditioner blows fuses or trips circuit breakers 
_______________________________________________________ 
 
Too many appliances are being used on the same circuit.

 

Unplug or relocate appliances that share the same circuit. 
 

Time-delay fuse or circuit breaker of the wrong capacity is 
being used. 

Replace with a time-delay fuse or circuit breaker of the 

correct capacity. See “Electrical Requirements”. 
 

An extension cord is being used. 

Do not use an extension cord 

with this or any other appliance. 
 

You are trying to restart the air conditioner too soon after 
turning the unit off. 

Wait at least 3 minutes after turning the unit off 

before trying to restart the air conditioner. 
 
 
 
 
 
 
 
 

Summary of Contents for WAC6115R

Page 1: ...950 0075 revD Page 1 of 15 9 May 2007 WINDOW AIR CONDITIONER INSTALLATION AND OPERATION CATALOG NO PRODUCT CODE WAC6115R 420 0005 WAC8115R 420 0008...

Page 2: ...e safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and follow all safety instructions This is the safety alert symbol...

Page 3: ...installation Tools Needed The location should provide Flat Blade and Phillips screwdrivers Tape measure Level Drill and 3 32 or smaller bit Scissors Utility Knife Parts Supplied on some models Check t...

Page 4: ...screw located in lower right corner of air conditioner when air conditioner is in cabinet The electrical ratings for your air conditioner are listed on the model and serial number label The model and...

Page 5: ...shown 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET on some devices a green light will turn on 3 Press TEST Listen for a click Reset button will trip and on some devices a gree...

Page 6: ...lation or removal The location where the power cord exits the air conditioner Should be no more than 4 ft 122cm from a grounded 3 prong outlet Do not block the louvers on the front panel Do not block...

Page 7: ...own Complete Installation 1 Insert foam seal behind the top of the lower window 2 Pull left hand curtain out until it fits into the window channel sash and against the glass of the upper window Repeat...

Page 8: ...ious settings 2 Select mode See Mode 3 Select fan speed See Fan Speed 4 Set temperature See Temperature ______________________________________________________ MODE ____________________________________...

Page 9: ...e 1 to 24 hours 4 Press TIMER again or wait 10 seconds Timer indicator light will remain on Display will show current room temperature To set the timer to turn on the air conditioner changing the prev...

Page 10: ...0 seconds Indicator light on air conditioner control panel will remain on To set Timer to turn on air conditioner changing the previous settings 1 Turn on air conditioner 2 Adjust Mode to Cool Fan Onl...

Page 11: ...er cabinet _______________________________________________________ Annual Maintenance Your air conditioner needs annual maintenance to help ensure steady top performance throughout the year Call your...

Page 12: ...room Check the cooling capabilities of your room air conditioner Room air conditioners are not designed to cool multiple rooms The filter is dirty or obstructed by debris Clean the filter The inside e...

Page 13: ...CORD RATING amps 15 POWER CORD TYPE LCDI POWER CORD LENGTH 4 MIN CIRCUIT BREAKER SIZE A 15 MIN CIRCUIT CAPACITY A 6 9 REFRIGERANT CHARGE lbs oz R22 0 81 13 SOUND dba H M L 62 59 57 4 WAY AIR ADJUSTME...

Page 14: ...G amps 15 POWER CORD TYPE LCDI POWER CORD LENGTH 4 MIN CIRCUIT BREAKER SIZE A 15 MIN CIRCUIT CAPACITY A 9 5 REFRIGERANT CHARGE lbs oz R22 1 72 27 5 SOUND dba H M L 56 52 49 4 WAY AIR ADJUSTMENT NO 2 W...

Page 15: ...ger registration period This warranty provides free replacement of defective parts only Labor and replacement parts as a result of normal wear and tear are not covered under this warranty Additional c...