background image

950-0075-revD 

Page 1 of 15 

9 May 2007 

 

WINDOW 

AIR CONDITIONER 

INSTALLATION 

AND 

OPERATION 

 

 

 

 

   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

              

 

CATALOG NO. 

PRODUCT CODE 

WAC6115R 420-0005 

WAC8115R 420-0008 

Summary of Contents for WAC6115R

Page 1: ...950 0075 revD Page 1 of 15 9 May 2007 WINDOW AIR CONDITIONER INSTALLATION AND OPERATION CATALOG NO PRODUCT CODE WAC6115R 420 0005 WAC8115R 420 0008...

Page 2: ...e safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and follow all safety instructions This is the safety alert symbol...

Page 3: ...installation Tools Needed The location should provide Flat Blade and Phillips screwdrivers Tape measure Level Drill and 3 32 or smaller bit Scissors Utility Knife Parts Supplied on some models Check t...

Page 4: ...screw located in lower right corner of air conditioner when air conditioner is in cabinet The electrical ratings for your air conditioner are listed on the model and serial number label The model and...

Page 5: ...shown 1 Plug power supply cord into a grounded 3 prong outlet 2 Press RESET on some devices a green light will turn on 3 Press TEST Listen for a click Reset button will trip and on some devices a gree...

Page 6: ...lation or removal The location where the power cord exits the air conditioner Should be no more than 4 ft 122cm from a grounded 3 prong outlet Do not block the louvers on the front panel Do not block...

Page 7: ...own Complete Installation 1 Insert foam seal behind the top of the lower window 2 Pull left hand curtain out until it fits into the window channel sash and against the glass of the upper window Repeat...

Page 8: ...ious settings 2 Select mode See Mode 3 Select fan speed See Fan Speed 4 Set temperature See Temperature ______________________________________________________ MODE ____________________________________...

Page 9: ...e 1 to 24 hours 4 Press TIMER again or wait 10 seconds Timer indicator light will remain on Display will show current room temperature To set the timer to turn on the air conditioner changing the prev...

Page 10: ...0 seconds Indicator light on air conditioner control panel will remain on To set Timer to turn on air conditioner changing the previous settings 1 Turn on air conditioner 2 Adjust Mode to Cool Fan Onl...

Page 11: ...er cabinet _______________________________________________________ Annual Maintenance Your air conditioner needs annual maintenance to help ensure steady top performance throughout the year Call your...

Page 12: ...room Check the cooling capabilities of your room air conditioner Room air conditioners are not designed to cool multiple rooms The filter is dirty or obstructed by debris Clean the filter The inside e...

Page 13: ...CORD RATING amps 15 POWER CORD TYPE LCDI POWER CORD LENGTH 4 MIN CIRCUIT BREAKER SIZE A 15 MIN CIRCUIT CAPACITY A 6 9 REFRIGERANT CHARGE lbs oz R22 0 81 13 SOUND dba H M L 62 59 57 4 WAY AIR ADJUSTME...

Page 14: ...G amps 15 POWER CORD TYPE LCDI POWER CORD LENGTH 4 MIN CIRCUIT BREAKER SIZE A 15 MIN CIRCUIT CAPACITY A 9 5 REFRIGERANT CHARGE lbs oz R22 1 72 27 5 SOUND dba H M L 56 52 49 4 WAY AIR ADJUSTMENT NO 2 W...

Page 15: ...ger registration period This warranty provides free replacement of defective parts only Labor and replacement parts as a result of normal wear and tear are not covered under this warranty Additional c...

Reviews: