8.2.1.3 Inbits Tab
Intbits
Displays inbit state. Above picture shows that limits switches are active (there is contact between the inputs to
ground).
NOTE!
You can jumper any desired input signal to ground and verify with this window that the CNC sees that the input closes.
8.2.1.4 Diagnostic Tools Tab
External stop when plasma arc is lost
Check or uncheck for feature to be turned ON/OFF (default ON). Turning this feature
OFF will let the plasma process continue to be ran even if plasma arc goes OFF. Apply needs to be pressed to activate
the change. Changing the setting does not save it permanently, rebooting the CNC will reset it to its original state.
External stop when marking is lost
Check or uncheck for feature to be turned ON/OFF (default ON). Turning this feature
OFF will let the marking process continue to be ran even if marking ok signal is lost (if plasma is used for marking
same as above). Apply needs to be pressed to activate the change. Changing the setting does not save it permanently,
rebooting the CNC will reset it to its original state.
Joystick latch time
Time value for direction key to latch. If set to example 5 seconds, keeping left direction button pressed
in for more than 5 seconds, the CNC will continue to drive left even if button is not pressed. Pressing any directional
button the machine will stop. Apply needs to be pressed to activate the change. Changing the setting does not save it
permanently, rebooting the CNC will reset it to its original state.
Hold activates below programmed
speed Speed % value for activating hold signal. Changing the setting does not save it
permanently, rebooting the CNC will reset it to its original state.
Logical status
Shows the logical status of external stop and limit switches.
Enable drives
Forces software enable to ON state.
Create diagnostics
Creates diag.zip, this contains diagnostic information about the CNC. File is saved to c:\robo\Diags
Summary of Contents for iCNC Performance
Page 6: ...This Page Intentionally Blank...
Page 17: ...iCNC Performance Manual 0 5401 SAFETY INSTRUCTIONS 1 5 This Page Intentionally Blank...
Page 42: ...iCNC Performance 5 2 INPUT POWER Manual 0 5401 This Page Intentionally Blank...
Page 54: ...iCNC Performance 6 12 iHC Manual 0 5401 This Page Intentionally Blank...
Page 84: ...iCNC Performance 7 30 iCNC SETUP Manual 0 5401...
Page 108: ...iCNC Performance A 6 APPENDIX A Manual 0 5401 I...