SERVICE
5-24
Manual 0-4640
5
G. No arc or intermittent arc in torch; Gas flows; AC
, GAS
, and DC
indicators ON;
TEMP indicator
off
1. Gas pressure set incorrectly (too high)
a. Reset gas pressure per pressure setting label on power supply.
2. Oil/moisture in air lines
a. Put the ON / OFF switch in the ON (up) position. Put the RUN / RAPID AUTO RESTART / SET switch in
the SET (down) position.
b. Place a welding filter lens in front of the torch and turn on the air. Any oil or moisture in the air will be visible on the
lens.
Do not start an arc!
c. Purge system. If problem corrected, add filters in line with air source.
3. Incorrect torch parts
a. Inspect the torch parts; replace as needed.
4. Faulty leads
a. Check torch leads continuity.
5. Faulty torch
a. Check torch.
6. Faulty connection of wire #58 or 62 to Pilot Board
a. Check wiring connection. Refer to the System Schematic in the Appendix. Connections should be:
• Wire #58 to Pilot Board terminal E58
• Wire #62 to Pilot Board terminal E62
If wires 58 and 62 are not connected to the proper terminals, replace the Pilot Board.
7. Faulty Main PC Board
a. Check for approximately 12 vdc at TP4
on Logic PC Board to TP1 on Main PC Board. If less than 2 vdc, replace the
Main PC Board.
8. Faulty Logic Board or Faulty Pilot Board
a. Install a jumper between wires 58 and 62 on Pilot Board and retry piloting. If torch pilots with jumper installed, replace
Pilot Board. If torch does not pilot, replace Logic Board.
Summary of Contents for CUTMASTER SL100SV
Page 8: ......
Page 42: ...INSTALLATION 3 18 Manual 0 4640 3 This Page Left Blank...
Page 119: ...Manual 0 4640 6 5 PARTS LISTS 6 This Page Left Blank...
Page 123: ...Manual 0 4640 6 9 PARTS LISTS 6 This Page Left Blank...
Page 132: ...PARTS LISTS 6 18 Manual 0 4640 6 This Page Left Blank...
Page 161: ...Manual 0 4640 A 29 APPENDIX A This Page Left Blank...