INTRODUCTION
2-2
Manual 0-4640
2
Power Supply Dimensions & Weight
Ventilation Clearance Requirements
22.5"
0.57 m
58 lb / 26 kg
A-03700
10.75"
273 mm
16.375"
416 mm
Art # A-03379
6"
150 mm
24"
0.6 m
6"
150 mm
6"
150 mm
2.03 Input Wiring Specifications
Voltage
Freq.
1-Ph
3-Ph
1-Ph
3-Ph
(Volts)
(Hz.)
(kVA)
(kVA)
(Amps) (Amps)
1-Ph
3-Ph
1-Ph
3-Ph
1-Ph
3-Ph
208
60
9
39
60
10
10
230
60
9
37
60
10
10
400
50
8
11
15
12
12
400
60
8.5
12
15
12
12
460
60
14
17.5
25
12
12
460
60
8
10
15
12
12
CutMaster 51 Power Supply Input Wiring Requirements
Input
Power Input
Current Input
Suggested Sizes (See Notes)
Fuse (Amps)
Wire (AWG)
Wire (Canada)
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
Power Input Current Input
Voltage Frequency
3-Ph
3-Ph
Fuse (Amps)
Wire (mm
2
)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
CE CutMaster 51
400
50
7.9
11.5
15
4
Input
Suggested Sizes (See Notes)
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
CE CutM aster 51 Input Wiring Specifications
NOTES
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
Cable conductor temperature used is 167° F (75° C).
An energy limiting fuse UL Class RK-1 (examples: BUSS LPS / LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
NEVER
use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.
Summary of Contents for CUTMASTER SL100SV
Page 8: ......
Page 42: ...INSTALLATION 3 18 Manual 0 4640 3 This Page Left Blank...
Page 119: ...Manual 0 4640 6 5 PARTS LISTS 6 This Page Left Blank...
Page 123: ...Manual 0 4640 6 9 PARTS LISTS 6 This Page Left Blank...
Page 132: ...PARTS LISTS 6 18 Manual 0 4640 6 This Page Left Blank...
Page 161: ...Manual 0 4640 A 29 APPENDIX A This Page Left Blank...