SECTION 3: INSTALLATION PROCEDURES
12
Manual 0-2746
• If using a fork lift vehicle, place and secure unit on a
proper skid before transporting.
• This unit has a handle mounted on top of the enclo-
sure for hand lifting only. Be sure unit is lifted and
transported safely and securely.
WARNING
HANDLE
is not for mechanical lifting.
3.05 Input Power Connections
The Power Supply accepts input voltages from 208V to
460V. Input can be 50 or 60 Hz, single-phase or three-
phase.
The Power Supply is factory-wired for 230V single-phase
or 460V three-phase input depending on the order. For
any other input voltage, the Power Supply must be
changed using the procedure in Sections 3.06.
A. Electrical Connections
The power source must conform to local and national elec-
tric codes. Recommended circuit protection and wiring
requirements are shown in Appendix I.
B. Opening Power Supply Enclosure
The left side panel of the Power Supply must be removed
to gain access to the input power connections and the
input voltage selection.
WARNING
Disconnect primary power at the source before as-
sembling or disassembling the Power Supply, torch
parts, or torch and leads assemblies.
1. Using a phillips head screw driver remove the five
screws which secure the left side panel (viewed from
front of unit) to the frame assembly.
Screws
(5 Places)
Left Side
Panel
A-00910
Ground Wire
Figure 3-1 Removing Left Side Panel
NOTE
There is a ground wire connection to the Left Side
Panel on the inside of the unit.
2. Carefully pull the Left Side Panel up and away from
the unit to gain access to the inside of the unit.
3.06 Input Voltage Selection
NOTE
For power supplies to use 575 VAC input power,
the unit must be setup for 460V three-phase op-
eration and the 575V Transformer Accessory must
be installed.
The Power Supply has three voltage settings; 208/230/
240VAC, 380/415VAC, or 460VAC. Power Supplies are
factory-wired for 230V single-phase or 460VAC three-
phase input depending on the order. Input voltage selec-
tion is accomplished by switching a wire harness con-
nector inside the Power Supply. Also, a jumper wire must
be properly installed depending on the input used.
WARNING
Disconnect primary power at the source before as-
sembling or disassembling the power supply, torch
parts, or torch and leads assemblies.
1. Move the power selection plug to the desired input
connection for 208/230/240V, 380/415V, or 460V op-
eration per the label attached to the panel.
Summary of Contents for CE PAK Master 75XL
Page 1: ...Manual No 0 2746 August 23 1999 Operating Manual A 02464 Air Plasma Cutting Power Supply...
Page 3: ...Purchase Date Power Supply Torch Record Serial Numbers For Warranty Purposes...
Page 4: ......
Page 41: ...Manual 0 2746 35 APPENDIX This Page Left Blank...
Page 43: ...Manual 0 2746 37 APPENDIX A 02503 OK OK TO MOVE 8 11 99...
Page 44: ...APPENDIX 38 Manual 0 2746...