6.05 Fault Finding Tests
A. Diode Testing Basics
WARNING
Disconnect primary power at the source before disassembling the power supply, torch, or torch leads.
Testing of diode modules requires a digital volt/ohmmeter that has a diode test scale. Remember that even if the
diode module checks good, it may still be bad. If in doubt, replace the diode module.
1. Remove AC power. Refer to Appendix 3 Wiring diagram.
2. Locate the IGBT diode module to be tested.
3. Remove P5 from IGBT module.
4. Set digital volt/ohmmeter to diode test scale.
5. Connect the volt/ohmmeter positive lead to the anode (+) of the diode and the negative lead to the cathode (-) of the
diode for forward bias testing (refer to following figure). A properly functioning diode will conduct in the forward
bias direction and indicate between 0.3 to 0.9 volts.
0.75
VR COM
A
Art # A-00307
Anode
Cathode
Forward Bias
Diode Conducting
+
_
Diode Test Symbol
Testing Diode Forward Bias
Summary of Contents for C-70A CUTSKILL
Page 2: ......
Page 4: ......
Page 6: ......
Page 12: ...GENERAL INFORMATION 1 6 Manual 0 4699 This Page Left Blank...
Page 16: ...Installation 3 2 Manual 0 4699 This Page Left Blank...
Page 20: ...Operation 4 4 Manual 0 4699 This Page Left Blank...
Page 35: ...Manual 0 4699 7 3 Parts List Art A 07757 1 2 3 Art A 07758 4 5 6 7 8 9...
Page 36: ...Parts List 7 4 Manual 0 4699 Art A 07759 10 11 13 6 Art A 07760 14 15 16 17 18 19 20 21...
Page 39: ...Manual 0 4699 7 7 Parts List 5 6 3 4 2 7 7 A 07060 1 8...
Page 40: ...Parts List 7 8 Manual 0 4699 This Page Left Blank...
Page 43: ...Manual 0 4699 A 3 APPENDIX This Page Left Blank...
Page 48: ...APPENDIX A 8 Manual 0 4699 This Page Left Blank...