Manual 0-4699
6-1
TROUBLE SHOOTING
SECTION 6:
TROUBLESHOOTING
WARNING
There are extremely dangerous voltage and power levels present inside this unit. Do not attempt to diagnose or repair
unless you have had training in power electronics measurement and troubleshooting techniques.
NOTE:
All procedures are done with the cover removed.
6.01 Setup and Operation
1.
Connect the unit to air supply and power.
2.
Connect the work lead clamp to cleaned area of work surface.
3.
Turn the switch located on the front panel, to the "On" position. The
A/C indicator on the front panel
should light and the cooling fan should be on.
4.
Set the air pressure. Press the Air Set Button
and set the regulator pressure to 75 psi (5.2 bar) (.52 MPa).
Air should be flowing continuously. Press the Air Set Button
again to stop the air flow.
NOTE:
If the Air Error Indicator light is on, check for low or no air pressure.
5.
Squeeze the torch trigger (slight delay), pilot arc starts.
6.
To begin cutting, transfer arc to work surface before the pilot goes out.
Summary of Contents for C-70A CUTSKILL
Page 2: ......
Page 4: ......
Page 6: ......
Page 12: ...GENERAL INFORMATION 1 6 Manual 0 4699 This Page Left Blank...
Page 16: ...Installation 3 2 Manual 0 4699 This Page Left Blank...
Page 20: ...Operation 4 4 Manual 0 4699 This Page Left Blank...
Page 35: ...Manual 0 4699 7 3 Parts List Art A 07757 1 2 3 Art A 07758 4 5 6 7 8 9...
Page 36: ...Parts List 7 4 Manual 0 4699 Art A 07759 10 11 13 6 Art A 07760 14 15 16 17 18 19 20 21...
Page 39: ...Manual 0 4699 7 7 Parts List 5 6 3 4 2 7 7 A 07060 1 8...
Page 40: ...Parts List 7 8 Manual 0 4699 This Page Left Blank...
Page 43: ...Manual 0 4699 A 3 APPENDIX This Page Left Blank...
Page 48: ...APPENDIX A 8 Manual 0 4699 This Page Left Blank...