Operation
4-2
Manual 0-4699
4.02 Preparations For Operating
At the start of each operating session:
WARNING
Disconnect primary power at the source before
assembling or disassembling power supply, torch
parts, or torch and leads assemblies.
A. Torch Parts Selection
Check the torch for proper assembly and appro-
priate torch parts. The torch parts must correspond
with the type of operation, and with the amperage
output of this Power Supply (70 amps maximum).
Use only genuine manufactured parts with this
torch.
Electrode
9-8215
Start Cartridge
9-8213
Tip
9-8231
Shield Cup
9-8218
Art # A-04432
B. Torch Connection
Check that the torch is properly connected.
C. Connect Work Cable
Make a clean work cable
connection to the work-
piece or cutting table
Work Cable
And Clamp
Art # A-04389
D. Torch Operation
• Refer to Section 1 for necessary safety precau-
tions.
3
4
Art # A-03383
Trigger
2
1
Trigger Release
Summary of Contents for C-70A CUTSKILL
Page 2: ......
Page 4: ......
Page 6: ......
Page 12: ...GENERAL INFORMATION 1 6 Manual 0 4699 This Page Left Blank...
Page 16: ...Installation 3 2 Manual 0 4699 This Page Left Blank...
Page 20: ...Operation 4 4 Manual 0 4699 This Page Left Blank...
Page 35: ...Manual 0 4699 7 3 Parts List Art A 07757 1 2 3 Art A 07758 4 5 6 7 8 9...
Page 36: ...Parts List 7 4 Manual 0 4699 Art A 07759 10 11 13 6 Art A 07760 14 15 16 17 18 19 20 21...
Page 39: ...Manual 0 4699 7 7 Parts List 5 6 3 4 2 7 7 A 07060 1 8...
Page 40: ...Parts List 7 8 Manual 0 4699 This Page Left Blank...
Page 43: ...Manual 0 4699 A 3 APPENDIX This Page Left Blank...
Page 48: ...APPENDIX A 8 Manual 0 4699 This Page Left Blank...