5.05 Basic Troubleshooting Guide
WARNING
There are extremely dangerous voltage and power levels present inside this unit. Do not attempt to diagnose or repair
unless you have had training in power electronics measurement and troubleshooting techniques.
Problem - Symptom Possible Cause
Recommended Action
ON / OFF Switch
is ON but the A/C
Indicator does not
light
1. Primary power disconnect is in
OFF position.
2. Primary fuses / breakers are
blown or tripped.
3. Faulty components in unit.
1. Turn primary power disconnect switch to ON position.
2. a) Have qualified person check primary fuses / breakers.
b) Connect unit to known good primary power receptacle
3. Return to authorized service center for repair or replacement.
FAULT indicator
flashing, 65 PSI
indicator flashing
1. Incorrect Primary line Voltage.
2. Primary input voltage problem.
3. Faulty components in unit.
1. Check that appropriate line voltage is connected to unit.
2. Have qualified person check primary voltage to insure it
meets unit requirements see section 2.04.
3. Return to authorized service center for repair or replacement.
TEMPERATURE
indicator ON. FAULT
indicator flashing.
1. Air flow through or around the
unit is obstructed.
2. Duty cycle of the unit has been
exceeded
3. Failed components in unit
1. Refer to clearance information – section 2.04
2. Allow unit to cool.
3. Return to authorized service center for repair or replacement.
GAS indicator OFF,
FAULT and MIN
pressure indicators
flashing.
1. Gas supply not connected to
unit.
2. Gas supply not turned ON.
3. Gas supply pressure too low.
4. AIR PRESSURE CONTROL
regulator set too low.
5. Failed components in unit.
1. Connect gas supply to unit.
2. Turn gas supply ON.
3. Set air supply inlet pressure to unit to 120 psi.
4. Adjust regulator to set air pressure - see section 4.02.
5. Return to authorized service center for repair or replacement.
FAULT and 70 PSI
indicators flashing.
1. Shield Cup loose.
2. Torch not properly connected to
power supply.
3. Problem in torch and leads PIP
circuit.
4. Failed components in unit.
1. Hand tighten the shield cup until it is snug.
2. Insure torch ATC is securely fastened to unit.
3. Replace torch and leads or return to authorized service center
for repair or replacement.
4. Return to authorized service center for repair or replacement.
FAULT and 75 PSI
indicators flashing.
1. Start signal is active when ON/
OFF SWITCH is turned to ON
position.
2. Problem in the torch and leads
switch circuit.
3. Failed components in unit.
1. Start can be active for one of the following:
• Hand torch switch held closed
• Hand pendant switch held closed
• CNC START signal is active low
Release the START signal source
2. Replace torch and leads or return to authorized service center
for repair or replacement.
3. Return to authorized service center for repair or replacement.
Summary of Contents for A-08950
Page 4: ...This Page Intentionally Blank ...
Page 8: ...This Page Intentionally Blank ...
Page 16: ...CUTMASTER 12mm GENERAL INFORMATION 1 8 Manual 0 5077 This Page Intentionally Blank ...
Page 24: ...CUTMASTER 12mm INTRODUCTION 2T 4 Manual 0 5077 This Page Intentionally Blank ...
Page 34: ...CUTMASTER 12mm OPERATION 4 4 Manual 0 5077 This Page Intentionally Blank ...
Page 48: ...CUTMASTER 12mm OPERATION 4T 14 Manual 0 5077 This Page Intentionally Blank ...
Page 69: ...CUTMASTER 12mm Manual 0 5077 5 21 SERVICE This Page Intentionally Blank ...
Page 73: ...CUTMASTER 12mm Manual 0 5077 5 25 SERVICE This Page Intentionally Blank ...
Page 77: ...CUTMASTER 12mm Manual 0 5077 5 29 SERVICE This Page Intentionally Blank ...
Page 78: ...CUTMASTER 12mm SERVICE 5 30 Manual 0 5077 This Page Intentionally Blank ...
Page 89: ...CUTMASTER 12mm Manual 0 5077 6 9 PARTS LIST A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Page 98: ...CUTMASTER 12mm PARTS REPLACEMENT 7 8 Manual 0 5077 This Page Intentionally Blank ...
Page 107: ...This Page Intentionally Blank ...