CUTMASTER 12mm
Manual 0-5077
5-3
SERVICE
5.04 Fault Indicator
At initial power up, two lights will temporarily illumi-
nate for 2-3 seconds to show the version of software used.
To determine the first digit, count the function indicators
left to right, 1 through 5. To determine the second digit
count the pressure indicators, reading from bottom to
top, 0 through 7. In the example below the Temp indica-
tor and 75 psi indicators are ON indicating the version
would be 2.3.
A
+
PSI
BAR
MAX
MAX
MIN
MIN
!
1 2 3 4
Art# A-07988
MIN
MAX
0
1
2
3
4
5
6
7
5
When the
!
"Fault" indicator is ON or blinking it
will be accompanied by one of the pressure indica-
tor lights depending on what the Fault is. Only one
of these faults will be displayed at one time. If more
than one fault exists, when the first fault is corrected
and cleared, the next fault will then be displayed. It
is possible to have a fault indicated in the function
indicators and another fault indicated in the pres-
sure indicators. The following table shows each of
the Faults possible.
Pressure
Indicator
Fault
Max
Over Pressure
90
Internal Error
85
Shorted Torch
80
Consumables Missing
75
Start Error
70
Parts in Place
65
Input Power
Min
Under Pressure
NOTE
Fault explanations are covered in the following
tables.
Explanation of Faults
" UNDER PRESSURE: Indicates that operating pres-
sure is set too low and power supply output
power will be disabled.
PART IN PLACE: Indicates that the shield cup is not
properly installed or tightened.
START ERROR: Indicates that the START SIGNAL
was active (ie. Torch Trigger depressed, hand held
pendant switch ON or CNC signal for torch ON)
during one of three conditions:
1) During initial power up when ON/OFF
switch is turned to ON position
2) When fault which had been disabling the
system is cleared.
3) When the FUNCTION CONTROL SWITCH
Mode is moved from SET position to any of
the other three (3) modes of operation.
CONSUMABLES MISSING: Indicates that the elec-
trode, start cartridge or tip is missing or exces-
sively worn.
SHORTED TORCH: Indicates the torch or lead has
a shorted condition between positive and nega-
tive leads.
INTERNAL ERROR: Indicates a microprocessor er-
ror.
OVER PRESSURE: Indicates that operating pressure
is set too high. The Error Indicator will not flash
when the pressure is above 95 PSI. This LED will
remain ON and the system will operate but pilot
starting and cut performance may be affected.
NOTE
The cooling fans will turn ON as soon as the unit
is turned ON. After the unit is idle for ten (10)
minutes the fans will turn OFF. The fans will come
back ON as soon as the torch switch (Start Signal)
is activated or if the unit is turned OFF, then turned
ON again. If an over temperature condition occurs,
the fans will continue to run while the condition
exists and for a ten (10) minute period once the
condition is cleared.
Summary of Contents for A-08950
Page 4: ...This Page Intentionally Blank ...
Page 8: ...This Page Intentionally Blank ...
Page 16: ...CUTMASTER 12mm GENERAL INFORMATION 1 8 Manual 0 5077 This Page Intentionally Blank ...
Page 24: ...CUTMASTER 12mm INTRODUCTION 2T 4 Manual 0 5077 This Page Intentionally Blank ...
Page 34: ...CUTMASTER 12mm OPERATION 4 4 Manual 0 5077 This Page Intentionally Blank ...
Page 48: ...CUTMASTER 12mm OPERATION 4T 14 Manual 0 5077 This Page Intentionally Blank ...
Page 69: ...CUTMASTER 12mm Manual 0 5077 5 21 SERVICE This Page Intentionally Blank ...
Page 73: ...CUTMASTER 12mm Manual 0 5077 5 25 SERVICE This Page Intentionally Blank ...
Page 77: ...CUTMASTER 12mm Manual 0 5077 5 29 SERVICE This Page Intentionally Blank ...
Page 78: ...CUTMASTER 12mm SERVICE 5 30 Manual 0 5077 This Page Intentionally Blank ...
Page 89: ...CUTMASTER 12mm Manual 0 5077 6 9 PARTS LIST A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Page 98: ...CUTMASTER 12mm PARTS REPLACEMENT 7 8 Manual 0 5077 This Page Intentionally Blank ...
Page 107: ...This Page Intentionally Blank ...