TITAN-C SERIES USER MANUAL
38
Instruction
Camera Instructions Received
Note
Read current
GAMMA
value
Receive
AA 04 00 3D 00 EB EB AA
The return value of the
movement is 1 byte,
indicating the current
GAMMA value *10. In the
example, the return value
is 0x0A, indicating the
current GAMMA value is
10/10=1.0.
Return
55 05 00 3D 33 0A D4 EB AA
Setting DDE
switch
Receive
DDE on: AA 05 00 3E 01 01 EF EB
AA
DDE off: AA 05 00 3E 01 00 EE EB
AA
Return
55 05 00 3E 33 01 CC EB AA
Read current
DDE switch
status
Receive
AA 04 00 3E 00 EC EB AA
Return
DDE on: 55 05 00 3E 33 01 CC EB
AA
DDE off: 55 05 00 3E 33 00 CB EB
AA
DDE Gear set
Receive
AA 05 00 3F 01 03 F2 EB AA
Such as: DDE tap is set
to 3.
Return
55 05 00 3F 33 01 CD EB AA
Reads the
current DDE
tap
Receive
AA 04 00 3F 00 ED EB AA
The return value of the
movement is 1 byte,
indicating the current
DDE tap. In the example,
the return value is 0x02,
indicating the current DDE
tap is 2.
Return
55 05 00 3F 33 02 CE EB AA
Simulated
video image
freezing
Receive
Freeze: AA 05 00 32 02 01 E4 EB
AA
Thaw: AA 05 00 32 02 00 E3 EB AA
Return
55 05 00 32 33 01 C0 EB AA
Digital
video image
freezes
Receive
Freeze: AA 05 00 32 02 02 E5 EB
AA
Thaw: AA 05 00 32 02 03 E6 EB AA
Return
55 05 00 32 33 01 C0 EB AA
Analog video
switch
Receive
On: AA 05 01 3D 02 01 F0 EB AA
Off: AA 05 01 3D 02 00 EF EB AA
Return
55 04 3D 33 01 CA EB AA
Image filter
Settings
Receive
Filter off: AA 05 00 31 01 00 E1 EB
AA
Filter on: AA 05 00 31 01 01 E2 EB
AA
Return
55 05 00 31 33 01 BF EB AA
CONTINUED FROM PREVIOUS TABLE