![Thermal Camera ICITitan1024C-0-09 User Manual Download Page 29](http://html1.mh-extra.com/html/thermal-camera/icititan1024c-0-09/icititan1024c-0-09_user-manual_1103205029.webp)
TITAN-C SERIES USER MANUAL
29
Instruction
Camera Instructions Received
Note
Read SN
code
Receive
AA 04 00 00 00 AE EB AA
Example:
The SN code returned
is the ASCII code of
A9181010, and if the
number of digits is
insufficient, it returns 00.
Return
55 0E 00 00 33 41 39 31 38 31 30
31 30 00 00 3B EB AA
Read PN
code
Receive
AA 04 00 01 00 AF EB AA
Such as:
In the example, he returned
ASCII code of PN code is
HD1024001Y00000XCNQ1,
and the insufficient number
of digits returns 00.
Return
55 18 00 01 33 48 44 31 30 32 34
30 30 31 59 30 30 30 30 30 58 43
4E 51 31 39 EB AA
Read FPA
width
Receive
AA 04 00 02 00 B0 EB AA
The return value is 2
bytes, with the low byte
first. In the example, the
return value is 0x80,0x01,
indicating that the FPA
width is 1024.
Return
55 06 00 02 33 00 04 94 EB AA
Read FPA
height
Receive
AA 04 00 03 00 B1 EB AA
The return value is 2
bytes, with the low byte
first. In the example, the
return value is 0x20,0x01,
indicating that the FPA
width is 768.
Return
55 06 00 03 33 00 03 94 EB AA
Read FPA
temperature
Receive
AA 04 00 04 00 B2 EB AA
Such as:
The reading temperature
is 30.7 ℃, then return
30.70x100 ℃, that is 3070
(decimal), low bytes in
front. If it’s negative, the
temperature is returned as
a complement.
Return
55 06 00 04 33 FE 0B 9B EB AA
Read camera
temperature
Receive
AA 04 00 05 00 B3 EB AA
Such as:
If the reading temperature
is 10.7 ℃, 10.70x100 ℃
is returned, that is, 1070
(decimal), with the lower
bytes first. If it’s negative,
the temperature is
returned as a complement.
Return
55 06 00 05 33 37 04 CE EB AA
Save setting
Receive
AA 04 00 11 01 C0 EB AA
Return
55 05 00 11 33 01 9F EB AA
Recover
Receive
AA 04 00 12 02 C2 EB AA
Return
55 05 00 12 33 01 A0 EB AA