TITAN-C SERIES USER MANUAL
13
I
O
-C
640
I
O
-C
380
Pixel Resolution
640 x 512
384 x 288
Operation Range
-40 °C to 80 °C (-40 °F to 176 °F)
Storage Range
-45 °C to 85 °C (-49 °F to 185 °F)
Detector Type
Uncooled VOx microbolometer
Pixel Pitch
12 μm
Spectral Band
8 μm to 14 μm
Thermal Sensitivity (NETD)
< (40 mK) 0.04 °C at 25 °C (77°F)
Frame Rate
25 Hz (PAL) or 50 Hz (NTSC)
Dimensions (without lens)
21 mm x 21 mm (L x W x D ± 0.5 mm)
(0.83” x 0.83” (L x W x H ± 0.02”))
1
Power
1.8V; 3.3V; 5V DC, < 0.60W
2
1.8V; 3.3V; 5V
DC,
< 0.55W
2
Power Protection
Over-voltage; Under-voltage; Reverse Connection
Weight (without lens)
< 142 g (8.88 oz) ± 3 g (0.11 oz)
Zoom
0.25X ~ 2.0X continuous zoom
Interface
RS-232; UART (3.3 V); I
2
C
Expansion Board
Available
Video
Analog: 1 Chanel PAL or NTSC
Digital: USB2.0; BT.656
Video Mirror
Horizontal; Vertical; Diagonal
Image Polarity
White hot or black hot
Image Processing
Digital filter; Imaging denoising; D
etail enhancement
Emissivity Correction
0.01 to 1.0
Recticle
R
eveal; Hidden; Shift
Humidity
5% to 95% non-condensing
Pixel Operability
> 99 %
Shock
80 G
Vibration
6 G
Includes TEC support
Palette support
Internal non-uniformity correction (NUC)
Level/Span adjustment; Brightness adjustment